Timer - Vulcan-Hart C24EA3 Service Manual

C24ea series atmospheric steamers
Hide thumbs Also See for C24EA3:
Table of Contents

Advertisement

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW
LOCKOUT / TAGOUT PROCEDURES.
REMOVAL AND REPLACEMENT
NOTE: The basic and professional model steamers
use the same 60 minute timer. When the timer
reaches zero, an external buzzer will sound and
steam will stop entering the cooking compartment.
The Professional steamer has extra components to
utilize the constant steam setting allowing the
steamer to operate continuously.
1.
Remove RIGHT SIDE PANEL as outlined under
COVERS AND PANELS.
2.
Note electrical connections then disconnect
wiring to timer.
PROFESSIONAL MODEL SHOWN
3.
Pull knob from timer shaft.
A.
Remove rotary shaft seal from timer shaft
then remove timer from front panel.
B.
Inspect rotary shaft seal. Replace if
damaged, worn or signs of moisture
migration into control area around timer
shaft is evident.
MODEL C24EA - TIMER

TIMER

4.
Reverse procedure to install.
5.
Check steamer for proper operation.
Page 17 of 52
F25213 (May 2006)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C24ea5C24ea series

Table of Contents