A.
Install valve with the inlet (ON) side of
valve connected to the back panel port and
the outlet (OFF) side of valve connected to
the water level control plumbing. Apply
liquid thread sealant to threads of piping
before assembly.

BUZZER

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove the RIGHT SIDE PANEL.
2.
Locate the buzzer which is mounted above the
door switch near the front of steamer.
3.
Disconnect electrical wiring from the buzzer and
door switch.
4.
Remove door striker.
5.
Remove remaining hardware securing door
switch mounting bracket to front panel then
remove door switch mounting bracket, door
switch and buzzer as an assembly.
6.
Remove buzzer from door switch mounting
bracket.
MODEL C24EA - SWITCHES, BUZZER AND SOLENOIDS
Page 33 of 52
7.
Reassemble parts removed in reverse order.
Perform DOOR LATCH ADJUSTMENT as
outlined under DOOR.