Other chemical properties in water supplies can also affect good steam generation and vary from within each state
and locality.
The water level probes in the steam generator tank use ions in the water to detect the water level. Do not use fully
demineralized or de-ionized water since it is non-conductive and the water level can not be detected.
NOTE: The use of strainers, or filters will not remove minerals from the water.
Steamers that operate over a long period of time without the benefit of properly conditioned water, which have
developed a heavy scale build up, should be cleaned before connecting to a conditioned water supply.
REFERENCE MATERIAL
For replacement parts, refer to Catalog of
Replacement Parts F-43123.
For operation, care and cleaning instructions, refer to
Installation and Operation Manual F-35428.
LUBRICATION
Component
Lubrication Type
Heating Element
Never Seez
Screws
All NPT Fittings
Pipe Thread Sealant, Loctite
565
Door Handle
Lubriplate 630AA
Sliding Bracket
TOOLS
•
Standard set of hand tools.
•
VOM with A/C current tester (any quality VOM
with a sensitivity of at least 20K ohms per volt
can be used).
•
Anti Static Kit, part no. TL - 84919.
Special
•
Torque Wrench - Capable of measuring
70 in*lb.
•
Aluminum Foil Tape - (McMaster-Carr Part No.
7631A21) or equivalent.
MODEL C24EA - GENERAL
•
Pressure Gauge Assembly
•
•
•
•
Page 5 of 52
Low Pressure Gauge - 0 to 5 psi.
recommended (Grainger Part No. 2C641).
Water Hose Coupling - swivel type
(Grainger Part No. 4KG87).
Reducer Bushing (Grainger Part No.
6MN61).
Pipe thread sealant (as required).
F25213 (May 2006)