Vulcan-Hart C24EA3 Service Manual page 7

C24ea series atmospheric steamers
Hide thumbs Also See for C24EA3:
Table of Contents

Advertisement

REAR PANEL
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove screws securing top cover to rear
panel and rear panel to steamer frame.
SCREW LOCATION
NOTE: If incoming plumbing or drain interferes with
rear panel removal, turn off water supply and
disconnect plumbing to machine.
2.
Remove LEFT SIDE PANEL.
3.
Disconnect vacuum relief hose from fitting.
TOP COVER REMOVED FOR CLARITY
4.
Pull bottom of rear panel away from machine
and plumbing.
5.
Reassemble parts removed in reverse order.
MODEL C24EA - COVERS AND PANELS
Page 7 of 52