1.14 Load curve – resistive load
Altitude above sea
Temperatur-Derating-Factor
level
2000 m
1
2500 m
0.953
3000 m
0.906
3500 m
0.859
4000 m
0.813
4500 m
0.766
▶ 2.If derating is required, shift all the points in the derating curve by the
temperature derating factor.
Calculation example for shifting the derating curve
Carry out the calculation and shift the derating curve as required
for your application
→ Section 1.13, "Derating"
72
70
60
50
40
30
20
10
3
24
27
0
0
10
20
30
Figure 6:
Example: Shifted derating curve (blue) at altitude of 3000 m above sea level
1000
500
200
100
50
20
10
0,1
0,2
0,5
1
Figure 7:
Load curve of the relay – resistive load
ESR5-NO-31-24VDC 11/23 MN049018EN Eaton.com
1 Description ESR5-NO-31-24VDC
Example
27 °C x 0.906
55 °C x 0.906
49
40
50
55
60
T
[°C]
A
2
5
10
I [A]
DC
24 °C
49 °C