Eaton ESR5-NO-31-24VDC Manual page 38

Emergency-stop and protective door monitoring
Table of Contents

Advertisement

6 Appendix
35
Digital inputs : Logic S12, S22
Number of inputs
Input description
Input voltage range "0"-signal
Input current range "0"-signal
Input voltage range "1"-signal
Inrush current
Current consumption
Filter time
Maximum permissible total cable resistance
Simultaneity
Suppressor circuit
Digital inputs: start circuit S34
Number of inputs
Input description
Input voltage range "1"-signal
Inrush current
Current consumption
Filter time
Maximum permissible total cable resistance
Simultaneity
Suppressor circuit
ESR5-NO-31-24VDC 11/23 MN049018EN Eaton.com
2
safety-related
0 V DC ... 5 V DC (S12)
0 mA ... 2 mA
20.4 V ... 26.4 V (S12)
< 100 mA (normally with U
at S12)
S
> -100 mA (normally with U
at S22))
S
38 mA (normally with U
at S12)
S
-38 mA (normally with U
at S22)
S
No test pulses allowed.
50 Ω
Suppressor diode
1
not safety related
20.4 V ... 26.4 V
< 6 mA (normally at U
)
S
1 mA (normally at U
)
S
No test pulses allowed
50 Ω
Suppressor diode

Advertisement