Graco Jockey 24Z764 Instructions Manual page 43

Automatic lubrication system
Hide thumbs Also See for Jockey 24Z764:
Table of Contents

Advertisement

A7- Constant Alarm Output ON Fault
This changes the behavior of the alarm output in a fault
from either toggling once per second (default) or steady
on.
1. The default OFF dis-
plays. The alarm out-
put toggles once per
second.
2. Press the UP and DOWN
ARROW buttons to change
OFF to ON on the display,
and to change the alarm
output to steady on.
3. Press the ENTER button to exit
Advanced Programming.
A9 - Toggle Low Level Output on Low Level
Warning or Fault
This changes the behavior of the low level output in a
warning or fault from either steady on (default) or tog-
gling once per second.
1. The default OFF dis-
plays. The alarm out-
put toggles once per
second.
2. Press the UP and DOWN
ARROW buttons to change
OFF to ON on the display, and
to change the alarm output to
steady on.
3. Press the ENTER button to exit
Advanced Programming.
3A5082N
A10 - Low Level Reset Upon Power On.
(Models with Firmware 5.04 and later. DMS
Models with Firmware 7.07 and later.)
This changes the behavior of the low level upon pump
power on. When A10 is on, a low level fault clears when
the pump power is cycled. The pump revolves 5
revolutions, checking to see if the low level condition is
still present. If not, it self clears and continues. If a low
level condition exists during the 5 revolutions, it goes
into a low level fault.
Low Level ON LED illuminates (F
F
. 35
IG
1. The default OFF
displays. The alarm
output toggles once
per second.
2. Press the UP and
DOWN ARROW button to
move through Advanced
Options until Advanced
Option A10 displays.
3. Press the ENTER button.
Pump
. 35).
IG
43