Description
3.1 Technical features and ambient conditions
3.1.4
Defining the direction of rotation
Direction of rotation
If the built-in torque motor is connected with a phase sequence U-V-W, and is fed from a three-
phase system with a clockwise phase sequence, then the rotor rotates clockwise. You can
identify the direction of rotation by viewing the DE of the built-in torque motor. The cable outlet
of the built-in torque motor is on the opposite side - the NDE.
Figure 3-3
3.1.5
Ambient conditions for fixed operation
Classify the environmental conditions for stationary use at weather-protected locations
according to the standard DIN IEC 60721‑3‑3. The environmental effects and their limit values
are defined in various classes in this standard.
With the exception of environmental parameters "Low air temperature" and "Low air
pressure", the motors satisfy climate class 3K3.
Table 3-2
Ambient parameter
a)
b)
c)
d)
e)
f)
g)
34
Line of sight for determining the direction of rotation
Ambient conditions are based on climate class 3K3
Low air temperature
High air temperature
Low relative humidity
High relative humidity
Low absolute humidity
High absolute humidity
Rate of temperature change
1)
Operating Instructions, 09/2022, A5E52220812B AA
Unit
Value
°C
- 5
°C
+ 40
%
5
%
85
g/m
1
3
g/m
3
25
°C/min
0.5
1FW6 built-in torque motors