• To free jammed parts of the body (e.g. hands, fingers, feet), pull apart components that are
clamped together.
– Do this using the non-magnetic hammer to drive the non-magnetic wedges into the
– Release the jammed body parts.
• If necessary, call the emergency medical service or an emergency physician.
Material damage caused by strong magnetic fields
NOTICE
Data loss caused by strong magnetic fields
If you are close to the rotor (< 100 mm) any magnetic or electronic data medium as well as
electronic devices that you are carrying can be destroyed. For example, credit cards, USB sticks,
floppy disks and watches are at risk.
• Do not carry any magnetic/electronic data media and no electronic devices when you are
3.1.3
Technical features
Table 3-1
Standard version of the 1FW6 built-in torque motor
Technical feature
Type of motor
Type of construction
Degree of protection according to
DIN EN 60034-5
Cooling method
Pressure in the cooling circuit
1FW6 built-in torque motors
Operating Instructions, 09/2022, A5E52220812B AA
separating rift.
close to a rotor!
Version
Synchronous motor with permanent magnet rotor
•
High number of poles, rotor pole number from 22 up to 98
Individual components
•
Stator
•
Rotor
Motor: IP23
•
The final degree of protection (minimum degree of protection: IP54) of the
installed motor must be realized by the machine manufacturer
Water cooling
•
Jacket cooling:
sizes 1FW6090, 1FW6130, 1FW6150
•
Integrated cooling (1 cooling circuit):
frame sizes 1FW6050 and 1FW6060
•
Integrated cooling (2 cooling circuits):
frame sizes 1FW6160, 1FW6190, 1FW6230, 1FW6290
Max. 10 bar (static)
3.1 Technical features and ambient conditions
Description
31