Electrolux VARIO STEAM S33-E Operating & Installation Instructions Manual page 51

Pressure steamer
Table of Contents

Advertisement

Microprocessor (MP) versions
of electrically heated appliances
Code/
Date of
colored mark
introduction
STEAM1 / yellow
15.05.86
STEAM2 / yellow
07.04.89
05.98
STEAM 12
from series
no. 81600480
from series
STEAM 13
no.20700086
STEAM 22
12/98
from series
STEAM 23
no.20700086
ADJUSTING THE CONTROL BOARD
Pressureless scope
Remove the cover in accordance with §5. Open the door. Preheat the appliance to 80°C container temperature. When
the temperature is reached the contactor (K1) switches off.
Adjusting with a millivoltmeter:
- Hold the negative phase of the voltmeter to the contact "0V"
- Hold the positive phase of the voltmeter to the contact "SENSOR"
- Read the voltmeter and write down the voltage (normal values 490 – 550 mV)
- Hold the positive phase of the voltmeter to the contact "0BAR"
- Hold the negative phase of the voltmeter to the contact "0V"
- Turn the potentiometer "P0" until the voltage of the voltmeter corresponds to the figure measured above.
Scope pressure 1 bar
Close the door. Operate the appliance with 1 bar. The pressure gauge on the operating panel must show 1 bar precisely.
If there is any deviation, the potentiometer (P1) must be adjusted until the pressure gauge shows 1 bar.
Cooking time
The digital display (DZ) must match the cooking time that has been set for time preselection using the potentiometer
(GZ). The operating knob must be adjusted if there is any deviation.
- Prise the cap off the operating knob with a knife
- Set the digital display with the knob to a typical value (e.g. 10 min.)
- Loosen the nut in the center of the knob
- Turn the knob on the spindle until the marking matches the value on the scale (10 min.)
- Tighten the nut in the center of the knob
- Replace the cap on the operating knob.
Buzzer
See power board (LP)
Service Manual Pressure Steamer
Standard program;
appliances
with
thermostatic
ventilation valve (EG)
Special program for Migros;
timer starts when the pressure
reaches 0.45 or 0.95 bar
respectively.
New standard program;
ventilation of the compartment is
achieved by opening the drain
valve
(AV)
(appliances
thermostatic
ventilation
(EG)).
New standard version,
same functions as STEAM 12
Programs for the Netherlands;
functions as no. 12. Additional:
timer starts when the pressure
reaches 0.45 or 0.95 bar
respectively.
New standard version,
same functions as STEAM 22
Remarks
This microprocessor cannot
used for appliances with serial
numbers
higher
81600480.
This version is downwards
compatible, i.e. it can be used
for
appliances
without
microprocessors.
valve
This microprocessor may only
be used together with the
newest control board (version
from series no. 20700086).
This microprocessor may only
be used together with the
newest control board (version
from series no. 20700086).
than
with
older
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

599062

Table of Contents