Remove and Replace the SSD

Step 9
Press the handle so that it catches the edge of the chassis and presses the security module all the way in.
Step 10
Using your fingers, tighten the captive screw on the front of the security module; if using a screw driver, tighten to no
more than 3 in-lbs.
Tightening the captive screws with your fingers is unlikely to lead to stripped or damaged captive screws.

Remove and Replace the SSD

There are two SSDs in each security module. They are configured in a RAID 1 configuration. If one or both
SSDs fail, you must decommission the security module and acknowledge the slot to start the SSD installation
and update the inventory. See the "Security Module/Engine Management" chapter in the
Chassis Manager Configuration Guide
can remove the SSDs, install the new SSDs, and acknowledge the slot to bring the security module back
online.
Note
Once you replace the SSD, the storage controller rebuilds the newly installed SSD and no loss of data should
occur. If both SSDs fail, no data can be recovered.
Note
The two SSDs in RAID 1 store each other's data. Breaking the RAID pair to use in another service module
causes the service module to fail discovery by the Supervisor.
Step 1
Decommission the security module.
Step 2
To remove an SSD, face the front of the chassis, press the handle release on the SSD and gently pull it out of the slot.
Cisco Firepower 9300 Hardware Installation Guide
62
for the instructions. After you decommission the security module, you