Remove and Replace the SSD

Remove and Replace the SSD
There are two SSDs in each security module. They are configured in a RAID 1 configuration. If one or both
SSDs fail, you must decommission the security module and acknowledge the slot to start the SSD installation
and update the inventory. See the "Security Module/Engine Management" chapter in the
Chassis Manager Configuration Guide
can remove the SSDs, install the new SSDs, and acknowledge the slot to bring the security module back
online.
Note
Once you replace the SSD, the storage controller rebuilds the newly installed SSD and no loss of data should
occur. If both SSDs fail, no data can be recovered.
Note
The two SSDs in RAID 1 store the other's data. Breaking the RAID pair to use in another service modules
causes the service module to fail discovery by the Supervisor.
Step 1
Decommission the security module.
Step 2
To remove an SSD, face the front of the chassis, press the handle release on the SSD and gently pull it out of the slot.
Figure 45: Remove the SSD
1
Handle
Step 3
To replace the SSD, hold the SSD in front of slot 1, push it in gently until it is seated, and close the handle.
Cisco Firepower 9300 Hardware Installation Guide
66
for the instructions. After you decommission the security module, you
2
Handle release