Installation menu If Ekip Touch detects that Rating Plug or Measurement module have not been installed properly, it signals
Test Menu
About Menu
50 | © 2023 ABB | 1SDH001330R1002 - ECN000297030
an alarm (page 291) and completes Settings menu with the specific installation section:
Menu
Submenus 1
Circuit Breaker
Installation
Correct installation is confirmed by a message on the display and disappearance of the alarm signal and
installation menu.
NOTE: availability of submenus depends on the module, which appears to have not been
installed
Menu
Submenus
Autotest
-
Trip Test
-
Test CB
-
Ekip Signalling 4K
(1)
-
Ekip Signalling 2K-1
Ekip Signalling 2K
Ekip Signalling 2K-2
(1)
Ekip Signalling 2K-3
S Protection
ZoneSelectivity
(2)
G Protection
Rc Test
-
(5)
available if one or more Ekip Signalling modules are connected and detected by Ekip Touch
(1)
available if Ekip Touch is on with auxiliary supply
(2)
available with S and/or S2 and/or D protection enabled, for S protection the set curve must be t=k
(3)
(4)
available with G and/or D protection enabled and curve t=kavailable with G and/or Gext and/or
MDGF and/or D protection enabled and curve t=k
available if the Ekip CI module is connected and detected by Ekip Touch
(5)
Menu
Submenus
Protection Unit
-
Protection Unit
-
Circuit Breaker
-
IEC 61557-12
-
(1)
Feature Collection
-
Modules
Modul x
Load Input Status
Power Controller
(3)
Load Active
Load Input Status
Load shedding
(3)
Load Active
available if Class 1 Power & Energy Metering SW package is provided for by Trip unit module or if it
(1)
has been previously activated
available if one or more modules are connected and detected by unit
(2)
Submenus 2
Rating Plug
Ekip Measuring
Description, parameters and Commands
Autotest command
TRIP command
Close CB , Open CB
Module autotest command
(1)
(1)
Module autotest command
(1)
(3)
Input , Force Output , Release Output
(4)
Test instructions
Information provided
Information about Ekip Touch: Trip unit serial
number, type, version, standard, SW version,
date and time, language
Information about Ekip Touch: Mainboard serial
number, Trip unit serial number, type, version,
standard, SW version, date and time, language
CB information: TAG name, CB name, rated
current, number of poles, CB status and
position, total operations, CB serial number
Status of 1% measurements (from Class 1 Power
& Energy Metering package), serial number of
assembly and current sensors connected
List of tripped protections in Trip unit
Module information: serial number, SW version,
(2)
status of inputs/outputs/contacts (if present)
Status of loads (open/closed)
Load configuration (activated/not activated)
Status of loads (open/closed)
Load configuration (activated/not activated)