Indicator Lamp In The Charging Station - Husqvarna AUTOMOWER 435X AWD Operator's Manual

Hide thumbs Also See for AUTOMOWER 435X AWD:
Table of Contents

Advertisement

6.5 Indicator lamp in the charging
station
For a fully functional installation, the indicator lamp in the charging station must emit a solid or flashing
green light. If something else appears, follow the troubleshooting guide below.
There is more help on www.husqvarna.com. If you still need help, please contact your local Husqvarna
representative.
Light
Cause
Solid green light
Good signals
Green flashing
The signals are good and
light
activated.
Blue flashing light
The boundary loop is not connected to
the charging station.
Break in the boundary loop.
Red flashing light
Interruption in the charging station's an-
tenna.
Solid red light
Fault in the circuit board or incorrect
power supply in the charging station.
The fault should be rectified by an au-
thorized service technician.
1035 - 001 - 04.02.2019
Action
No action required
ECO mode is
No action required.
Check that the boundary wire connec-
tors are fitted properly to the charging
station.
Find out where the break is. Replace
the damaged section of the loop with a
new loop wire, and splice using an orig-
inal coupler.
Contact your local Husqvarna repre-
sentative.
Contact your local Husqvarna repre-
sentative.
Troubleshooting - 45