Continue until only a very short section of
the wire remains which is the difference
between a solid green light and a flashing
blue light. Then follow instruction in step 5
below.
4.
If indicator lamp still flashes blue in step 3
above: Put AL and G1 back in their original
positions. Then switch AR and G1. If
indicator lamp now is lit with a solid green
light then disconnect AL and connect a new
boundary wire to AL. Connect the other end
of this new wire at the middle of the
suspected wire section. Follow the same
approach as in 3a) and 3b) above.
5.
When the break is found, the damaged
section must be replaced with a new wire.
Always use original couplers.
1035 - 001 - 04.02.2019
Troubleshooting - 49