Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately. Revision ANTAIRA Industrial 1-Port BNC/RJ11 4-Port Gigabit Ethernet Extender User's Manual For Models: IVC-4011-T-V2 Revision: 1.0 (JULY 2023) Part No.: 2350-AC0530-470...
1. Package Contents Thank you for purchasing ANTAIRA Industrial 1-Port BNC/RJ11 to 4-Port Gigabit Ethernet Extender, IVC-4011-T-V2. In the following sections, term “Industrial Ethernet Extender” means IVC-4011-T-V2. Open the box of the Industrial Ethernet Extender and carefully unpack it. The box should contain the following items: ...
2.2 Front View Front Panel Figure 2-2: IVC-4011-T-V2 Front Panel The unit’s front panel provides the following simple interfaces: LEDs for Power 1, Power 2 and VDSL2 4 10/100/1000BASE-T RJ45 ports BNC female/ RJ11 connector via DIP switch ...
The upper panel of the Industrial Ethernet Extender consists of one terminal block connector within two DC power inputs Figure 2-3: IVC-4011-T-V2 Top View 2.4 IVC-4011-T-V2 LED Indicators The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system.
Page 9
VDSL Color Function Indicates that the VDSL connection is established. Fast Indicates that the VDSL connection is in VDSL Green Blink training status (about 15 seconds). Slow Indicates that the VDSL connection is in idle Blink status. Indicates the Industrial Ethernet Extender is Green running in CO mode.
2.5 DIP Switch and Link Type Link Type The BNC mode allows Industrial Ethernet Extender to connect and transfer data by using BNC cable. The RJ11 mode allows Industrial Ethernet Extender to connect and transfer data by using telephone wire. ...
Page 11
When the Industrial Ethernet Extender operates in CPE mode, DIP switches 2, 3, and 4 are without function. Note DIP-2: Transmission (G. INP and Interleave mode) Method of protection against bursts from other devices G. INP or lines to impact your xDSL connection. Method of error correction used on xDSL connection.
3. Product Specifications Product IVC-4011-T-V2 Hardware Specifications TP interface 4 10/100/1000BASE-T RJ45 auto-MDI/MDI-X ports 1 BNC female Ethernet over Coaxial Coaxial cable: 75 ohm Cabling RG-6/U cable, less than12Ω/1000 ft RG-59/U cable, less than 30Ω/1000 ft. VDSL Maximum Max. 1200m with data transmission Distance (3,937ft.)
4. Applications The Industrial Ethernet Extender does not require any software configuration. Users can immediately use any feature of this product simply by attaching the cables and turning the power on. There are some key limitations on the Industrial Ethernet Extender. Please check the following items.
Page 15
4. Power, CO and CPE LEDs will illuminate correspondingly. 5. Connect coaxial cable from LAN1 IVC-4011-T-V2 to VDSL BNC port of the LAN2 IVC-4011-T-V2. 6. VDSL LNK LED will blink to illuminate at both Industrial Ethernet Extenders.
Refer to the following procedure to set up many pairs of IVC-4011-T-V2 to IP surveillance system. 1. Set the IVC-4011-T-V2 to be the CO and CPE mode from the DIP switch on the front panel. 2. Power on the IVC-4011-T-V2 by connecting its power source.
5. Hardware Installations 5.1 Wiring the Power Inputs The 6-contact terminal block connector on the top panel of Industrial Ethernet Extender is used for two DC redundant power inputs. Please follow the steps below to insert the power wire. When performing any of the procedures like inserting the wires or tightening the wire-clamp screws, make sure the power is OFF to prevent from getting an electric Caution...
1. The wire gauge for the terminal block should be in the range between 12 and 24 AWG. 2. The DC power input range is 12V ~ 48V DC and supports 24V AC. Note 3. Use one power input when using 24V AC. 5.2 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below.
5.3 Grounding the Device Users MUST complete grounding wired with the device; otherwise, a sudden lightning could cause fatal damage to the device. Earth Ground EMD (Lightning) DAMAGE IS NOT CONVERED UNDER WARRANTY. Note 5.4 DIN-rail Mounting Installation The DIN-rail bracket is screwed on the Industrial Ethernet Extender when out of factory.
Page 20
Step 2: Lightly insert the bottom of the switch into the track. Step 3: Make sure the DIN rail is tightly secured on the track. Step 4: Please refer to the following procedure to remove the Industrial Ethernet Extender from the track.
Step 5: Lightly pull out the bottom of DIN rail for removing it from the track. 5.5 Wall-mount Plate Mounting To install the Industrial Ethernet Extender on the wall, please follow the instructions described below. Step 1: Remove the DIN-rail bracket from the Industrial Ethernet Extender with a screwdriver.
IVC-4011-T-V2 units. Please also try to adjust the DIP switch of the IVC-4011-T-V2 to the other SNR mode. 2. Please note you must use one IVC-4011-T-V2 in CO mode and the other IVC-4011-T-V2 in CPE mode to make connection to each other work.
Generally speaking, the higher SNR value gets, the better the line quality gets, but performance is lower. Q3: What is the best distance for IVC-4011-T-V2? A3: In order to guarantee the stability and better quality of network, we suggest the distance should not exceed 1.2 kilometers.