Duerkopp Adler 867-M PREMIUM Operating Instructions Manual page 73

Table of Contents

Advertisement

Programming
Operating Instructions 867-M PREMIUM - 02.0 - 05/2017
Menu items
Setting option 1
Off
Monitor,
t Clean
 p. 71
Motor Stop
Softw.,
CounterType
Software
 p. 72
Counter
MotorStop
ResetNeces
Setting: Monitor (Monitor)
Monitor mode can only be used if the additional equipment of the
remaining thread monitor is present on the machine. Monitor mode
allows for optical monitoring of the bobbin. The possible settings
are listed in the table.
t Clean
Value range 0000 – 5000 [ms]
Motor Stop
ON/OFF
Setting option 2
Value range 0000 – 5000 [ms]
ON/OFF
A/B/C/D
Value range 00000 – 99999
ON/OFF
ON/OFF
Duration for which the lens is blown
clear with compressed air.
The process takes place as the thread
is cut.
Sewing stops and a notice is shown
on the display when the bobbin is
detected to be nearly empty. If the
parameter is not activated, only the
LEDs on the machine arm give a
warning if the bobbin is empty.
71