3.
Pull the needle out towards the bottom.
4.
Insert the new needle into the hole in the needle bar (1) until
it reaches the end stop.
Important
Align the needle in such a way that the groove (3) faces the hook (4).
5.
Tighten the screw (2).
Order
Always adjust the clearance between the hook and the needle after
changing to a different needle thickness ( Service Instructions).
Disturbance
An incorrect hook distance can cause the following disturbances:
• Changing to a thinner needle:
• Missing stitches
• Thread damage
• Changing to a thicker needle:
• Damage to the hook tip
• Damage to the needle