Assembly of the side housings
Insert the ball valves (11) into both seats on the
side housing (2) (see figure 12).
Put the o-ring on the valve stop (15) then screw
it into the side housing with spring and bolt.
Apply the o-ring manifold outside (21) on the side
housing's sleeves. Screw the shock absorbers (6)
to the side housing.
Assembly of the pump
Slide the set of assembly pins (23) into the both
diaphragms (17) and center housing (1). Slide both
side housings (2) onto the protruding assembly
pins. Add manifolds (3) between the side housing's
sleeves (do not forget to insert the o-ring manifold
inside (22) into them).
Slide both side housings together (important –
pay attention to where the air inlet connector
is located, so that it is easily accessible after
screwing the pump), taking care that the manifolds
are in the correct position, then add spring
washers and screw the dome nuts on one side.
Press down on the other side housing and add the
spring washers and screw the dome nuts on the
other side (see figure 14). Tighten the pump with
the appropriate torque values as mentioned on
page 22.
21-VA-MA_Manual_HC-PURE FD _en.indd 14
21-VA-MA_Manual_HC-PURE FD _en.indd 14
Figure 12
Figure 13
21-VA-MA_Manual_HC-PURE FD _en | 26.05.2023
Figure 14
14