3. Determine the location of the wall bracket on the wall.
a. Position the wall bracket flush against the wall above the
unit.
b. With the locking tab handle pushed down on the bracket,
position the bracket so that the locking tab sits completely
inside the cutout on the anti-tip plate.
• Move the anti-tip plate back-and-forth as necessary
to properly seat the locking tab inside the plate.
Secure the plate to the unit once the proper location is
determined.
c. Mark the locations for the wall bracket fasteners through
the holes on the wall bracket.
4. Pre-drill the holes in the wall at the marked locations for the
appropriate wall bracket fastening system.
5. Install the wall bracket using the appropriate fasteners.
6. Lift the locking tab handle on the wall bracket, and move
the unit in position underneath the wall bracket.
7. Release the locking tab handle so that the locking tab sits
completely inside the cutout on the anti-tip plate.

General

Use the following procedures to operate a Convected Drawer
Warmer.
WARNING
Read all safety messages in the IMPORTANT SAFETY
INFORMATION section before operating this equipment.
1. Plug the unit into an electrical receptacle of the
correct voltage, size, and plug configuration. See the
SPECIFICATIONS section for details.
2. Move the Power I/O (on/off) switch to the I (on) position.
The switch will illuminate.
• The digital temperature controller will energize and
the current temperature of the unit will appear on the
display.
• The phrase "out 1" will appear in the upper left corner of
the display to show that the unit is in heat mode.
BURN HAZARD:
• Some exterior surfaces on the unit will get hot. Use
caution when touching these areas.
• Use caution when opening drawer. Hot air escapes
when drawer is open.
CDWCEM-1123
CAUTION
Digital Temperature Controller
Model CDW-3N Control Panel
Anti-Tip Wall Bracket
Installing the Anti-Tip Wall Bracket
3. Press and release the
controller to verify the setpoint temperature.
• The setpoint temperature will be shown for 15
seconds. After 15 seconds, the display will revert
to the current temperature of the unit. To change the
setpoint temperature, refer to "Changing the Setpoint
Temperature" in this section.
"out 1"
Down Arrow
SET
Key
Digital Temperature Controller
NOTE: The digital temperature controller is pre-set to a
setpoint temperature of 91°C (195°F) at the factory.
Once the setpoint temperature is changed, the new
setpoint temperature will remain in memory until it is
changed again. The maximum setpoint temperature is
91°C (195°F).
4. Allow the unit 15–20 minutes to reach operating
temperature before loading preheated food product.
Power I/O Switch
7
INSTALLATION
Locking Tab Handle
Locking Tab
Screw
Anti-Tip Plate
(adjustable)

OPERATION

key on the digital temperature
Celsius
Symbol
Up Arrow
Key
Key