OPERATION

Control Board

The Control Board offers several features: you can e. g. simply set the starting
address.
Enter the menu by pressing the MODE button. You can change the selection by
pressing UP or DOWN. You can leave every mode by pressing the MODE button. The
functions provided are described in the following sections.
After you connected the effect to the mains, the LED WF-10 starts running and the
display indicates:
Main menu
Function
Stand-alone operation
p_ _
Master mode, automatic program mode
With the function you can run the internal programs p--1 - p--4.
DMX mode
512
With this function you can adjust via the UP or DOWN button the desired
DMX512 starting address.

DMX-controlled operation

You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.

Addressing

Each EUROLITE LED WF-10 occupies 2 DMX-channels. The Control Board allows you to select the DMX
starting address, which is defined as the first channel from which EUROLITE LED WF-10 will respond to the
controller.
If you set, for example, the address to channel 3, the LED WF-10 will use the channel 3 to 4 for control.
Please make sure that you don't have any overlapping channels in order to control each EUROLITE LED
WF-10 correctly and independently from any other fixture on the DMX data link.
If several EUROLITE LED WF-10 are addressed similarly, they will work synchronically.
Note:
The modes of DMX512 data are shown via the blinking control LED in the display of the device:
After switching on, the device will automatically detect whether DMX512 data is received or not. If the data is
received, the display will show "d.001" with the actually set address.
If there is no data received at the DMX-input, the display will show "d001" with the actually set address.
This situation can occur if:
- the 3 PIN XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective, if the cable or connector is defective or the signal wires are swap
in the input connector.
Note:
It's necessary to insert the XLR termination plug (with 120 Ohm) in the last device in the link in order to
ensure proper transmission on the DMX data link.