Displaying the Set Value
1. Press the
2. Press the
Changing the Set Value (i.e. the Required Temperature)
1. Press the
The set value is displayed and the
digital display.
2. The value may be increased or decreased with
digital display shows the required value.
3. Confirm the new value with the
will be stored automatically.
Automatic Defrosting
The appliance defrosts automatically 4 times over a 24-hour period.
The timer initiates with the first activation of the appliance.
EN
During the automatic defrosting process, the yellow indicator light on the operating
side of the appliance illuminates.
1. If there is a need for the change of automatic defrosting phases, press the
key and hold it pressed for 5 seconds.
The defrosting cycle will start immediately.
The digital display shows the
The defrosting cycle lasts approximately 20 minutes.
Then, the subsequent defrosting cycle is initiated after 6 hours.
NOTE!
Water generated during defrosting evaporates automatically.
Manual Defrosting
Additionally, aside of the automatic defrosting, manual defrosting may be activated
any time.
1. Press the
The manual defrosting is initiated.
The digital display shows the
18 / 24
key shortly, to display the set value.
key again or wait 5 seconds, to return to the previous message.
key for more than 2 seconds.
symbol.
key and hold it pressed for at least 5 seconds.
symbol.
Installation and operation
or
LED indicator light flashes on the
or
key or wait 10 seconds — then, the value
button until the