VOLTAGE MEASUREMENTS

WARNING
Use extra care when measuring voltages > 35 V DC and 25 V AC RMS.
1. Set the function switch to the V, mV, or LoZ position.
2. Insert the black probe into the COM terminal and red probe into
the V terminal.
3. Short press the MODE button to manually select AC or DC.
4. Connect the probes in parallel to the part under test.
5. Read the voltage value on the display.

RESISTANCE MEASUREMENTS

WARNING
Do not measure resistance on a powered circuit or component.
1. Set the function switch to the Ω position.
2. Insert the black probe into the COM terminal and red probe into
the Ω terminal.
3. Short press MODE to manually select resistance Ω.
4. Touch the tips of the probes across the circuit under test.
5. Read the measurement on the display.

CONTINUITY TESTS

WARNING
Do not measure continuity on a powered circuit or component.
1. Set the function switch to the Continuity
2. Insert the black probe into the COM terminal and red probe into
the Ω terminal.
#NAS100161; r. AC/92816/92816; en-US
Exit an extended icon function.
Short press to enable/disable the display backlight.
Long press to enable/disable the Worklights.
Enable/disable Bluetooth communication.
position.
4