Summary of Contents for Epilog Laser Fusion Pro 32
Page 1
303-215-9171 Overhead Camera Replacement Fusion Pro 32 & 48 Parts Required Tools/Materials Required • CS0834 - Assy, Camera Overhead • 5/16” Nut Driver or Adjustable Wrench • Phillips Head Screwdriver • Anti-Static Strap 07/2023...
Page 2
16000 - Overhead Camera Replacement Overhead Camera 5. Remove the camera cover to expose the camera assembly: Replacement Overhead Camera Removal 1. Turn off the engraver. 2. Disconnect the engraver from power. 3. Open the top door of the engraver: 6.
Page 3
16000 - Overhead Camera Replacement 8. Loosen and remove the four (4) 1/4” 2. Place the camera assembly over the nuts that secure the camera assembly camera mounting studs on the top to the top door: door: 9. Remove the camera assembly from 3.
Page 4
16000 - Overhead Camera Replacement Updating the Cameras 5. Install the camera cover in the engraver: 1. At the display panel, press the gear icon in the upper right-hand corner of the display to open the Settings menu: 6. Install and tighten the six (6) Phillips screws which secure the camera cover to the top door: 2.
Page 5
4. Press Test & Update. 5. Allow the engraver to run the update process. After replacing the overhead camera, complete the camera calibration procedure. If further assistance is required, contact Epilog Laser Technical Support by phone at 303-2159171, or by email at tech@ epiloglaser.com.