Download Print this page

Epilog Laser Fusion Pro 32 Assembly Replacement

X-axis rail
Hide thumbs Also See for Fusion Pro 32:

Advertisement

Quick Links

X-Axis Rail Assembly Replacement
Parts Required
Pro 32 - CS1200 - X-Axis Rail Assembly
Pro 48 - CS0400 -X-Axis Rail Assembly
Fusion Pro 32 & 48
5/32" hex wrench
5/16" nut driver or wrench
Phillips head screwdriver
9/2022
www.epiloglaser.com
tech@epiloglaser.com
Tools Required
303-215-9171

Advertisement

loading

Summary of Contents for Epilog Laser Fusion Pro 32

  • Page 1 303-215-9171 X-Axis Rail Assembly Replacement Fusion Pro 32 & 48 Parts Required Tools Required • Pro 32 - CS1200 - X-Axis Rail Assembly • 5/32” hex wrench • Pro 48 - CS0400 -X-Axis Rail Assembly • 5/16” nut driver or wrench •...
  • Page 2 PRO 32 & 48 X-AXIS ASSEMBLY X-Axis Assembly Removal 5. Loosen the Phillips screw on the lens tube retaining collar. Make sure to hold the lens tube to ensure that it does not 1. Turn off the engraver. fall: 2. Disconnect engraver from power source. 3.
  • Page 3 PRO 32 & 48 X-AXIS ASSEMBLY 8. Loosen, but do not remove the four (4) 12. Disconnect the air tubing from the elbow connector at right side of the Phillips screws that hold the x-axis drive board cover: x-axis assembly: The air tubing is held by a retaining fixture.
  • Page 4 PRO 32 & 48 X-AXIS ASSEMBLY 14. Remove the x-axis drive board housing: 16. Lift the x-axis assembly upwards to clear the locator pins on the left and right y-axis bearing blocks: 15. Remove and or loosen the four (4) 5/32”...
  • Page 5 PRO 32 & 48 X-AXIS ASSEMBLY X-Axis Assembly Installation 3. Install and/or tighten the four (4) 5/32” fasteners that secure the x-axis assembly to the y-axis bearings. There 1. Slide the x-axis assembly into the are two (2) on the right side and two (2) engraver through the right side of on the left side: the machine, taking care to clear the...
  • Page 6 PRO 32 & 48 X-AXIS ASSEMBLY 7. Reconnect the seven (7) electrical 5. Install and tighten the four (4) 7/64” hex connectors from the drive board: screws that hold the x-axis drive board housing: The electrical connectors on the drive board are all unique and will only fit into one receptacle.
  • Page 7 PRO 32 & 48 X-AXIS ASSEMBLY 10. Position the lens tube in the lens Updates and Calibrations assembly, ensuring that the notch in the tube faces the rear of the engraver. The x-axis assembly contains many Make sure to hold the lens tube after components, including circuit boards, inserting to ensure that it does not fall: cameras, and a motor.
  • Page 8 PRO 32 & 48 X-AXIS ASSEMBLY 3. Enter the Diagnostics menu and scroll to 5. Allow the engraver to complete the the Camera tab. Press Test & Update: update. Once done, a success message will appear: 4. Press Update: Updating the Peripherals 1.
  • Page 9 PRO 32 & 48 X-AXIS ASSEMBLY Calibrating the Focus 2. Press Program to enter the Peripheral Update menu: Focus Calibrations for CO2- Only Engravers Focus calibration must be completed in the order outlined in this procedure. Table Calibration The table calibration is a crucial step in the laser focus calibration.
  • Page 10 PRO 32 & 48 X-AXIS ASSEMBLY 2. Once in the Settings menu, press 4. Allow the engraver to complete the the Focus button to enter the Focus calibration. Once complete, a success Commands/Calibrations menu: message should appear. Move to the CO2 Focus Procedure. CO2 Focus Calibration The CO2 focus calibration establishes the focal height of the laser and manual...
  • Page 11 PRO 32 & 48 X-AXIS ASSEMBLY 5. Once the job is running, press the Focus 9. Once the correct focal height has been button and slightly raise and lower the found, let go of the joystick and press table with the joystick while observing the Go/Stop button to stop the job.
  • Page 12 Thickness box. If using anodized Since the table will rise to depress the aluminum provided by Epilog Laser, the autofocus plunger, use the Jog feature default value of 0.025” corresponds to to position the lens carriage in a position the material.
  • Page 13 PRO 32 & 48 X-AXIS ASSEMBLY Focus Calibrations for 2. Once in the Settings menu, press the Focus button to enter the Focus Fiber- Only Engravers Commands/Calibrations menu: Focus calibration must be completed in the order outlined in this procedure. Table Calibration The table calibration is a crucial step in the laser focus calibration.
  • Page 14 PRO 32 & 48 X-AXIS ASSEMBLY 2. Once in the Settings menu, press 5. Allow the engraver to complete the the Focus button to enter the Focus calibration. Once complete, a success Commands/Calibrations menu: message should appear. Move to the Fiber Focus Procedure. Fiber Focus Calibration The CO2 focus calibration establishes the focal height of the laser and manual...
  • Page 15 12. Ensure that the material thickness used power to 3-5%: during the previous step is entered in the Thickness box. If using anodized aluminum provided by Epilog Laser, the default value of 0.025” corresponds to the material. 13. Press the Start button. This calibration is...
  • Page 16 PRO 32 & 48 X-AXIS ASSEMBLY Autofocus Calibration 3. Press the AF Plunger button: Before completing the table calibration install the raster table. Since the table will rise to depress the autofocus plunger, use the Jog feature to position the lens carriage in a position which will prevent the autofocus plunger and lens cone from coming into contact with the left and or top ruler guides.
  • Page 17 PRO 32 & 48 X-AXIS ASSEMBLY Before completing the table calibration 3. Press the Table button: install the raster table. Since the table will rise to depress the autofocus plunger, use the Jog feature to position the lens carriage in a position which will prevent the autofocus plunger and lens cone from coming into contact with the left and or top ruler guides.
  • Page 18 PRO 32 & 48 X-AXIS ASSEMBLY 1. Open your preferred illustrating 6. While raising and lowering the table, program and create a black, raster box find the height where the spark appears measuring ~2” x 2” or 50mm x 50mm. the brightest.
  • Page 19 16. Ensure that the material thickness used enter the Settings menu: during the previous step is entered in the Thickness box. If using anodized aluminum provided by Epilog Laser, the default value of 0.025” corresponds to the material. 12. Ensure that the material thickness used during the previous step is entered in the Thickness box.
  • Page 20 PRO 32 & 48 X-AXIS ASSEMBLY If completing the procedure on the Fusion Using the lower power setting allows you to Pro 48, place the artwork and material in more finely dial in the correct focal height the center of the engraving table, ensuring as the spark fades very quickly when the that the artwork appears over the anod- material becomes out of focus.
  • Page 21 Thickness box. If using anodized Since the table will rise to depress the aluminum provided by Epilog Laser, the autofocus plunger, use the Jog feature default value of 0.025” corresponds to to position the lens carriage in a position the material.
  • Page 22 4. Press the Start button. 5. Allow the engraver to complete the calibration. Once complete, a success message should appear. If further assistance is required, reach out to Epilog Laser Tech Support by phone at 303-215-9171, or by email at tech@epiloglaser.com.