Fig. 17: Adjusting screw A for axial safeguard
B
B
Fig. 18: Fastening screws B of coupling halves
6.7.2
Alignment of the pump unit
Installation and operating instructions • Wilo-Atmos GIGA-NHT • Ed.01/2023-10
Connect the coupling halves once correctly aligned.
The tightening torques for the coupling are listed in the table "Tightening torques for ad-
justing screws and coupling halves".
Install the coupling guard.
Coupling parameter d [mm]
80, 88, 95, 103
110, 118
125, 135
140, 152
160, 172
180, 194
200, 218
225, 245
250, 272
280, 305
315, 340
350, 380
400, 430
440, 472
Table 7: Tightening torques for adjusting screws and coupling halves
Any deviations in the measuring results indicate a misalignment. In this case, the unit must
be realigned to the motor.
Loosen the hexagon head screws and counter nuts on the motor.
Place shims under the motor feet until the height difference is compensated.
Pay attention to the axial alignment of the coupling.
Tighten the hexagon head screws again.
Finally, check the functioning of the coupling and shaft. The coupling and shaft must be
easy to turn by hand.
After correct alignment, mount the coupling guard.
For tightening torques for the pump and motor on the baseplate, see "Screw tightening
torques for pump and motor" table.
Screw:
M6
Tightening torque
10
[Nm]
Table 8: Screw tightening torques for pump and motor
CAUTION
Risk of damage due to vibrations! Incorrect alignment can lead
to vibrations.
Vibrations can damage or destroy individual components.
• Carefully align the pump unit until all measurement results are within
the permissible range.
Tightening torque for ad-
justing screw A [Nm]
4
4
8
8
15
25
25
25
70
70
70
130
130
230
M8
M10
M12
25
35
60
en
Tightening torque for ad-
justing screw B [Nm]
13
14
17.5
29
35
44
67.5
86
145
185
200
260
340
410
M16
M20
M24
100
170
350