Storage; Application/Use; Intended Use; Improper Use - Wilo Atmos GIGA-NHT Installation And Operating Instructions Manual

Table of Contents

Advertisement

en
3.2.2
Attaching the unit
Fig. 2: Attaching the unit
3.3

Storage

4

Application/use

4.1

Intended use

4.2

Improper use

12
Comply with applicable national safety regulations.
Use legally specified and approved lifting gear.
Select the lifting gear based on the prevailing conditions (weather, attachment point,
load, etc.).
Only attach the lifting gear to the attachment point. Fix in place with a shackle.
Never feed the lifting gear over or through transport lugs without protection.
Never feed the lifting gear over sharp edges without protection.
Use lifting equipment with sufficient bearing capacity.
The stability of the lifting equipment must be ensured during operation.
When using lifting equipment, ensure a second person is present to coordinate the pro-
cedure if required (e.g. if the operator's field of vision is blocked).
When lifting, make sure that the load limit of the lifting gear is reduced when pulling at an
angle. The safety and efficiency of the lifting gear is best guaranteed when all load-bear-
ing elements are loaded vertically. If necessary, use a lifting arm, to which the lifting gear
can be vertically attached.
Ensure the load is lifted vertically!
Prevent the suspended load from swinging!
NOTICE
Improper storage can lead to damage to the equipment.
Damage caused by improper storage is not covered by the guarantee or
warranty.
Requirements at the storage location:
dry
clean
well-ventilated
free from vibrations
free from humidity
free from rapid or extreme changes in temperature
Store the product somewhere safe against mechanical damage.
Protect the bearings and couplings from sand, gravel and other foreign objects.
Lubricate the unit to prevent rust and bearing seizing.
Manually rotate the drive shaft several times once a week.
Storage for more than three months
Additional precautionary measures:
All rotating parts must be coated with a suitable protective medium to protect them
from rust.
If the pump is to be stored for more than a year:
Seal the suction and pressure flange.
Grease the shaft end and protect it with a cap.
Store the pump horizontally.
Consult the manufacturer.
The glanded pumps from the Wilo-Atmos GIGA-NHT series are intended for use in district
heating systems or industrial applications with overheated water or heat carrier oil.
The Wilo-Atmos GIGA-NHT pumps may be used for:
Hot-water heating systems
Cooling and chilled water circulation systems
District heating loops up to 200 °C
Industrial water cycles up to 200 °C
Industrial heat carrier oil circuit systems up to 350 °C
The pumps are only approved for the fluids specified in the "Technical data" section.
WARNING! Misuse of the pump can lead to dangerous situations and damage.
Never use with fluids that have not been approved by the manufacturer.