Danfoss DEVIreg Room 140F1161 Installation Manual page 26

Intelligent electronic timer controlled thermostat with app control
Table of Contents

Advertisement

26
INSTALLATION GUIDE
DEVIreg™ Room
Warnings and error messages
Warning table
Warning
overwritten due
W1
to manual dial
W2
W3
Set temperature
W5
not achievable
Maximum Floor
W8
Temperature Limit
Temperature set
W10
above maximum
temperature limit
Description
Schedule
setting
Invalid clock
Child lock is
enable
reached
Set when Schedule is active (Set in App)
but dial has been turned to set a manual
setpoint
If time is totally invalid - less than 2021 or
above 2050 or use production date or rst
time connected to App
Will be active if child lock is enable and
the user tries to change the setpoint
or mode with the potentiometer (or
encoder)
Warning given when the room/ oor
temperature from schedule or manual
setpoint can't be reached within 40 PWM
periods (Output from heating control)
Set if Maximum Floor Temperature is
reached while in Combi Mode while
Room Temperature is not at Set point
Set, if maximum temperature is lower than
the current temperature knob/potentiometer
is pointing at. Like Max set to 25°C and knob
is set to 27°C
Reference