INSTALLATION GUIDE
DEVIreg™ Room
Breakout
To enable the thermostat to go up to a oor temperature of 45°C, or to
use the room only control functionality. a permanent modi cation must
be made, this can invalidate your warranty on the product and connected
products.
The higher maximum temperature limit or alternative control mode
needs to be set in the app after the action has been performed.
To best perform the action the thermostat unit needs to be dismounted
from the power supply, on the back of the thermostat there is a hole as
shown below, to perform the breakout the plastic seal in the hole needs
to be broken and thereafter the PCB trace needs to be broken. The action
is best performed with a athead screwdriver or similar as shown below.
whilst doing the breakout please take care not to damage any other
components on the circuit board.