Disposal Instruction ....14 Introduction ECtemp 532 is an electronic thermostat provided with a 2-pole switch, a room sensor to control the room tempera- ture, and an additional floor sensor to limit the maximum floor temperature.
Danfoss ECtemp 532 Technical Specifications Operation voltage 220-240 V~, 50 Hz Standby power consump- Max 0.25 W tion Relay: Resistive load Max 15 A / 3450 W @ 230 V Inductive load cos φ= 0.3 max 1A Sensing units NTC 15kOhm at 25°C Sensing values: 0 °C...
Danfoss ECtemp 532 Type Storage temperature -20 to +65 °C IP class Protection class Class II - Dimensions 85 x 85 x 36 mm Weight 90 g The product complies with the EN/IEC Standard “Automatic electrical controls for household and similar use”: •...
Danfoss ECtemp 532 Please also note the following: • The installation of the thermostat must be done by an authorized and qualified installer according to local regulations. • The thermostat must be connected to a power supply via an all-pole disconnection switch.
Page 7
Danfoss ECtemp 532 Do not place the thermostat on the inner side of an exterior wall. Always install the thermostat at least 50 cm. from windows and doors. Do not place the thermostat in a way that it will be exposed to direct sunlight.
Page 8
Danfoss ECtemp 532 Follow the steps below to mount the thermostat: Open the thermostat: • Press the release tab in the bottom of the ther- mostat using a flat object. • Carefully detach the front cover. • Carefully detach the frame.
Page 9
Danfoss ECtemp 532 Connect the thermostat according to the connection diagram. LOAD LOAD Mains Max. Load 220-240V~ 15 (1) A IP31 -10T30 D532 The screen of the heating cable must be connected to the earth conductor of the power supply cable by using a separate connector.
Danfoss ECtemp 532 Settings How to change the minimum and maximum floor temperatures Remove the adjust- ment button. Move the pins to the desired positions. Put the adjustment button back in place. Note: Please be aware of the following: • The floor temperature is measured where the floor sensor is placed.
Page 11
Danfoss ECtemp 532 Thermal Examples of Details Approximate resist- flooring setting for ance 25 °C on top [m²K/W] surface of floor 0,05 8 mm HDF based > 800 28 °C laminate kg/m³ 0,10 14 mm beech 650 - 31 °C parquet 800 kg/m³...
All work will be invoiced in full if Danfoss is required to inspect or repair faults that have arisen as a result of any of the above. The Danfoss warranty shall not extend to products which have not been paid in full. Danfoss will, at all times, provide a rapid and effective response to all complaints and inquiries from our customers.
Page 13
WARRANTY CERTIFICATE The Danfoss warranty is granted to: Address Stamp Purchase date Serial number of the product Product Art. No. *Connected output [W] Installation Date Connection Date & Signature & Signature *Not mandatory...