Application Macro 3-wire

This macro is intended for those applications where the drive is controlled
using momentary push-buttons. It gives two more preset speeds compared to
Factory Macro (1) by using DI4 and DI5.
The value of parameter 9902 is 2.
Input signals
• Start,stop and direction (DI1,2,3) • An. output AO: Frequency
• Analogue reference (AI1)
• Preset speed selection (DI4,5)
mA
*Constant speed selection: 0 = open, 1 = connected
DI4
DI5
Output
0
0
Reference through AI1
1
0
Constant speed 1 (1202)
0
1
Constant speed 2 (1203)
1
1
Constant speed 3 (1204)
Note! Stop input (
(local).
Application Macro 3-wire parameter values:
1001
1
EXT
COMMANDS
1002
2
EXT
COMMANDS
1003
DIRECTION
1102
1/
2
EXT
EXT
SEL
1103
1
EXT REF
SELECT
Output signals
• Relay output 1: Fault
• Relay output 2: Running
Control
Function
Terminals
1 SCR
2 AI 1
External reference1; 0...10 V <=> 0...50 Hz
3 AGND
4 10 V
Reference voltage 10 VDC
5 AI 2
Not used
6 AGND
7 AO
Output frequency 0...20 mA <=> 0...50 Hz
8 AGND
9 +12 V +12 VDC
10 DCOM
11 DI 1
Momentary activation with DI2 activated: Start
12 DI 2
Momentary deactivation: Stop
13 DI 3
Activate to reverse rotation: Fwd/Rev
14 DI 4
Constant speed select*
15 DI 5
Constant speed select*
16 RO 1A
17 RO 1B
18 RO 2A
19 RO 2B
2) deactivated: panel START/STOP button interlocked
DI
4 (
1
,2
DI
P
P
0 (
NOT SEL
3 (
REQUEST
6 (
1)
EXT
1 (
1)
AI
ac.maher.co.ir
,3)
1106
EXT REF
)
1201
CONST SPEED SEL
)
1601
RUN ENABLE
2105
PREMAGN SEL
2201
/
ACC
DEC
DIP switch S1
S1:1:U
Relay output 1
Fault: open
Relay output 2
Running: closed
2
0 (
SELECT
KEYPAD
8 (
4,5)
DI
0 (
NOT SEL
0 (
NOT SEL
1/2
0 (
SEL
NOT SEL
)
)
)
)