5.2 Example of ConfigureCmd

FPort:0x07
Bytes
1
CmdID
CmdID– 1 byte
DeviceType– 1 byte – Device Type of Device
NetvoxPayLoadData– var bytes (Max=9bytes)
Description
Device
Config
ReportReq
Config
ReportRsp
R718J2
ReadConfig
ReportReq
ReadConfig
ReportRsp
(1) Configure R718J2 device parameter MinTime = 1min、MaxTime = 1min、BatteryChange = 0.1v
Downlink: 0143003C003C0100000000
Device Return:
8143000000000000000000 (configuration success)
8143010000000000000000 (configuration failure)
(2) Read R718J2 device parameter
Downlink: 0243000000000000000000
Device Return:
8243003C003C0100000000 (device current parameter)
1
DeviceType
Cmd
Device
ID
Type
MinTime
0x01
(2bytes Unit: s)
0x81
0x43
0x02
MinTime
0x82
(2bytes Unit: s)
Var (Fix =9 Bytes)
NetvoxPayLoadData
NetvoxPayLoadData
MaxTime
(2bytes Unit: s)
Status
(0x00_success)
Reserved
(9Bytes, Fixed 0x00)
MaxTime
(2bytes Unit: s)
7
BatteryChange
(1byte Unit:0.1v)
(4Bytes, Fixed 0x00)
Reserved
(8Bytes, Fixed 0x00)
BatteryChange
(1byte Unit:0.1v)
(4Bytes, Fixed 0x00)
Reserved
Reserved