To change the operating voltage, remove the
fuse holder from the P10 Power Supply chassis.
Fuse A (see picture above) is located in a sleeve
that can be slid out of the body of the fuse
holder: by turning the sleeve and reinserting it,
the orientation of the contact pins is altered,
switching the operating voltage. The selected
voltage will appear in the small window in the
base of the fuse holder.
Make sure that if required, you change the
fuse values to match the new voltage (as above).
You can now reinsert the fuse holder.

2.3 Mains supply

Make sure to use a fully grounded AC power cord (one with three terminals – live, neutral and ground). Make
sure that the mains voltage selection of the unit matches your local mains voltage.
Do not connect your P10 phono-stage power supply unit to the AC supply/wall socket before connecting the
umbilicals between the power supply unit and audio chassis.
We recommend disconnecting the P10 from the AC supply in the following cases:
When making connections (we also recommend disconnecting the rest of the system from the AC supply
when installing signal and speaker cables).
When cleaning.
During thunderstorms.
When left unused for a long period.

2.4 Packaging and future transport

The P10 phono-stage must always be packed in its original carton for transportation. Doing so will ensure the
optimal level of protection for your unit. Therefore, keep all the packaging material in a dry and clean place for
future use.
Finally we recommend removal of the adjustable spikes, putting them into the holes provided in the packaging
foam for transportation. Indeed, vibrations during transport may cause the adjustment spikes to move from
their fully retracted position. There is then a risk of scratching the supporting surface when re-installing the unit.

2.5 Cleaning

Use a soft, dry towel or cloth for cleaning. Never use any solvent or liquids as they may damage the surface
treatment or penetrate inside the units.
The window should only be cleaned with a micro-fiber cloth, like those used for cleaning glasses, as the
plexiglass window is easily scratched, even by paper-tissues.