You can now select a particular response/impedance setting and apply it to the chosen input (by pressing the
Middle/OK button), or you can use it as a guide to repeat the test with a narrower range of values, using the
Bottom button to exit the program. You can repeat the process as often as you wish, but, normally two or three
times is sufficient to achieve an excellent result.
Due to the extremely fine range of loading adjustment available with the P10, once you have set the load using
the Loading Wizard, it is possible to further refine it over time by listening.

11.1 Interpreting the Loading Wizard display

The Loading Wizard generates frequency response curves for each cartridge, tonearm cable and load setting.
Rload = 220 U
Level = -29dB
1 kHz
The White line (Black on this diagram) traces the Left Channel output from 1Hz to 30kHz
The Red line traces the Right Channel output from 1kHz to 30kHz
MM/MC LOADING WIZARD
Acquisition complete.
Press UP and DOWN buttons to scroll
through measurements.
Press OK to use the displayed loading
value, CANCEL to abort.
Loading 5
MM/MC LOADING WIZARD
Left: Flatness = 1404
Right: Flatness = 1404
100 k U
2 kHz
Correctly loaded cartridge 
P10 User Manual
5 kHz
10 kHz
20 kHz