INSPECTION AND MAINTENANCE
ENOW00036-1A
When starting the outboard motor in the
test tank, make sure that:
1. Water level is at least 10 cm (4 in.) above
the anti-ventilation plate to avoid over-
heating of the engine.
2. Run at idling only
3. Remove the propeller
(See page 56)
3
2
1. Test tank
2. Water
3. Over 10 cm (4 in.)
ENOM00950-1
Fuse replacement (for SP type)
ENOW00923-1
10
Before replacing a fuse, disconnect the bat-
tery cable from the battery negative (-) ter-
minal first. Failure to properly remove
battery cables may cause a short-circuit.
ENOW00924-0
Never use a fuse with a rating that exceeds
the specified rating as this could cause seri-
ous damage to the electrical system.
If the fuse is blown, try to determine the
CAUTION
1
ENOF00863-0
CAUTION
CAUTION
cause and respond to the problem as
simply replacing the fuse will likely be
blown again. If you are unable to respond
to the cause or the fuse continues to
blow, request an authorized Tohatsu
dealer for inspection.
1. Stop the engine and disconnect the
battery cable from the battery nega-
tive (-) terminal.
2. Remove the engine cover.
3. Remove the fuse box lid.
4. Remove the fuse and check it. If the
fuse is blown, replace it with a fuse of
the same specified rating. The out-
board motor is supplied with spare
fuses in the spare fuse holder.
1
1. Blown fuse
ENOF01524-0