Target-Pro 2 Analyzer and Sampler
Operation Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Vickers Target-Pro 2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danfoss Vickers Target-Pro 2

  • Page 1 Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual...
  • Page 2: Table Of Contents

    Specifications and Part Numbers Troubleshooting Danfoss reserves the right to alter speci cations without notice. Except as permitted by such license, no part of this publication may be reproduced without prior written permission of Danfoss. O p e r a t i n g P r e c a u t i o n s Battery •...
  • Page 3: Target-Pro

    Clears last result • Recall #0 Recalls results from memory • Print Prints recalled results 7. + Contrast—Increases backlight intensity 8. – Contrast—Reduces backlight intensity Low Battery Indicator Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 4: Analyzer Set-Up

    ISO 17/15/12 (NAS6). These options only apply to the Continuous Test; ignore if other test types are selected. For detailed continuous sam- pling instructions, see pages 6–7. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 5: Running A Test

    2. Disconnect minimess con- 4. Remove waste fluid hose store. nector on sampling hose from analyzer. to isolate fluid supply. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 6: Continuous Sampling

    7. Between tests, status will show Waiting. 8. Press the stop button [2] at any point in the cycle to end continuous sampling. Test status will show Idle. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 7 Note: If you deselect log every test, the analyzer will only store the test results when the Target Cleanliness Level is achieved; this reduces memory storage demands. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 8 6. Connect the bottle sampling unit to the 12-volt DC power supply. If the collected fluid contains air, follow steps 7–10 to de- aerate the sample. Otherwise, skip to step 11. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 9: External Wiring Details

    (completed status). Relay 1 is also switched during Normal, Dynamic & Triple bottle test types. Relay will open at test end or when stop button is pressed. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 10: Memory Recall

    Auto Print mode. The LCD screen backlight dims automatically when the external power supply is not connected. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 11 1.5 m waste uid hose Dimensions Height 210mm; Depth 260mm; Width 430mm;Weight 7.6 kg Danfoss reserves the right to alter these speci cations without notice. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 12: Iso 4406 Cleanliness Code System

    0.32 0.08 0.16 0.04 0.08 0.02 0.04 0.01 0.02 0.01 Table 5: ISO 4406 Allocation of Scale Numbers ISO 4406 Cleanliness Code Chart (with 100ml sample volume) Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 13 General equipment components; 2. the operational conditions of the of limited reliability system; 3. and the required reliability and life 25–40 Low-pressure equipment expectancy. not in continuous service Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 14 This table is only a guideline. The exact relationship between ACFTD sizes and the NIST sizes may vary from instrument to instrument, depending on the characteristics of the parti- cle counter and original ACFTD calibration. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 15: Appendix

    APCs means the user can set minimum acceptablelevels. Benefits include improved calibration techniques and proce- dures, greater particle count reproducibility with different equipment, and more accurate and consistent filter test results. Vickers by Danfoss Target-Pro 2 Analyzer and Sampler Operation Manual V-PP-MC-0002-E July 2023...
  • Page 16 Phone: +86 21 2080 6201 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.