Danfoss SonoSafe Installation & User Manual

Danfoss SonoSafe Installation & User Manual

Energy meters
Hide thumbs Also See for SonoSafe:

Advertisement

Installation & User Guide
SonoSelect and SonoSafe
Energy Meters
www.heating.danfoss.com
09/2017
VUIGB802
© Danfoss
1

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss SonoSafe

  • Page 1 Installation & User Guide SonoSelect and SonoSafe Energy Meters www.heating.danfoss.com 09/2017 VUIGB802 © Danfoss...
  • Page 2 Strategy & portfolio Director Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation...
  • Page 3: Table Of Contents

    Disposal................15 VUIGB802 © Danfoss | Energy Meters | 2018.01 | 3...
  • Page 4: General

    Calculator at max. 45 °C to secure optimal conditions for battery lifetime. At media temperatures below ambient temperature (cooling) the calculator must be mounted separately from the flow sensor to prevent condensation. • Avoid installation stress from pipes and fittings. • Flush the system. 4 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 5: Identification Of Installation: Supply/Return Pipe Installation

    Rotation in pipe axis: Flow sensor should be angled in 45 can be collected. to 315° to avoid air collection in flow sensor. 2.4 Mounting orientation, calculator 4 x 90° VUIGB802 © Danfoss | Energy Meters | 2018.01 | 5...
  • Page 6: Mounting Of O-Ring And Temperature Sensor

    30.5 mm G1¼ 39mm Note: • Tolerance on machined dimensions = ± 0.5 mm. • Pipe fittings for use with probe type DS (Direct Short). : provision for security sealing. 6 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 7: Communication (Expansion Modules)

    SonoSelect and SonoSafe 2.6 Communication modules Modules in general To adapt the meter for various applications SonoSelect 10 and SonoSafe 10 features a slot for mounting communication modules. Each module features its own µ-controller and is powered by its own battery.
  • Page 8 Max 25 m E32 activates in meter if: Alarms 1) Module battery is empty 2) When no. of delayed pulses exceeds 5000 (incorrect scaling) *Default setting. Can be changed via SonoApp. 8 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 9 To ensure IP protection class connecting cable Cable specification Ø4.2 ± 0.1 mm outerjackets must be Communication cables delivered with heat meter. 1.0m Cable ends are stripped with crimped ferule. VUIGB802 © Danfoss | Energy Meters | 2018.01 | 9...
  • Page 10: Installation Of Module/Cable

    Close enclosure making sure that no cables interfere with rubber sealing and other internal parts. Reset tamper alarm via Sono-App for SonoSelect 10. For module configuration, see SonoApp user guide. 10 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 11: Battery

    Close enclosure making sure that no cables interfere with rubber sealing or other internal parts. Confirm battery change by pressing the button 2 times within 120 seconds. Reset tamper alarm (E13) via SonoApp for SonoSelect 10. VUIGB802 © Danfoss | Energy Meters | 2018.01 | 11...
  • Page 12: Commissioning

    Factory seal 3.4 IP class Calculator IP65 (SonoSelect) / IP54 (SonoSafe) Flow sensor IP65 Temperature sensor IP65 Note: The IP class can be compromised if cables are subjected to angled tension. 12 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 13: Function Overview

    LOOP 1 click Current Supply temp. Return temp. Display test/All on Power Flow LOOP 2 click History log Accounting date Monthly date 1 >> Monthly date 12 LOOP 3 click VUIGB802 © Danfoss | Energy Meters | 2018.01 | 13...
  • Page 14: Display Explanation

    Battery low (less than 12 months) Tamper alarm Supply Temperature Error High flow > qss Return Temperature Error Battery consumption too high Display overflow (energy/volume) Absolute/Difference temperature outside accumulated range Communication module error 14 | © Danfoss | Energy Meters | 2018.01 VUIGB802...
  • Page 15: Device Overview

    Flow sensor Brass, stainless steel, PPS Metal recovery (including transducer and liner) Transducer PZT, stainless steel, PEI Approved deposit for PZT Other plastic parts PC, PPS, PEI, TPE Plastic recovery VUIGB802 © Danfoss | Energy Meters | 2018.01 | 15...
  • Page 16 16 | © Danfoss | Energy Meters | 2016.09 VUIGB802...

This manual is also suitable for:

Sonoselect

Table of Contents