2.0 APPLIANCE DATA

Destination Country
GB - IE
Specifications
Main burner injector
Oxypilot
Gas Control
Gas Inlet
Ignition
Spark Gap
Please see Data Badge affixed to appliance for current data.
This appliance is for use only with the gas type, and at the pressure stated on the appliance Data Badge.

3.0 INSTALLATION REQUIREMENTS

If the appliance is to be sited near a disused or unserviceable fireplace served by a natural draught flue then the old flue must be sealed
off. It will be necessary to ventilate the old flue to prevent condensation and dampness forming, however any air vent used to ventilate
the old flue must not be sited within 1000mm of this appliance. If the flue can be ventilated to the outside of the building then this is
usually the best solution. If in doubt then advice should be sought from a local building control officer. The appliance is designed to be
floor mounted. If the appliance is to be mounted in front of a newly fabricated area of wall that also serves the purpose of sealing off
the old flue then it is very important that there are no holes, gaps or otherwise in this wall that will allow draughts from the old flue to
enter the room, especially directly behind the appliance. Such draughts could affect the performance of the ODS system and result in
nuisance cutting out, for example. If the gas supply pipe is to enter the appliance from the rear, i.e. emerge from the wall behind the appli-
ance, then any hole in the wall from which the pipe emerges must be tightly sealed. Propane/LPG models must not be installed in cellars,
basements or any room which is completely below ground level.

3.1 ROOM SIZING

The room size MUST be a minimum of 35m
This is to allow adequate circulation of air and ensure the correct operation of the fire. This volume may include adjacent spaces but
these spaces must not be separated by a door. Note : To calculate a room size in cubic metres (m
feet (ft
) by 35.3.
3

4.0 SITE REQUIREMENTS

This appliance may be installed in any room in the home except bathrooms. In accordance with BS5871 part 4, installation in bedrooms
is permitted. If the appliance is to be installed in a bedroom then an electronic carbon monoxide detector complying with the current
edition of BSEN 50291 must be installed in the same room as the appliance. For maximum safety it is recommended that such device is
continuously (mains) powered and arranged in such a way that the gas supply
to the appliance is isolated in the event of an alarm. The selection and instal-
lation of such device shall be in accordance with the current edition of BSEN
50292, and the user must be briefed regarding the use and maintenance of
such a device.
The appliance is designed to be versatile, and as such will operate correctly
when exposed to normal gentle draughts experienced within the home. It is
not recommended, however that the appliance be installed in areas where it
is likely to be directly exposed to persistent strong draughts, that may be gen-
erated by outside doors, windows, air vents, air conditioning units, extractor
fans, ceiling fans etc. See section 4.1 for more information on ventilation.
Clearances to non-combustible materials
Non combustible surfaces are defined as brick, metal, natural stone, concrete
etc. and also a number of man-made materials impervious to flame. If in doubt
refer to the material manufacturer for further information before proceeding
with installation.
Clearances to the sides of the appliance are 100mm (4"). Clearance to the
front of the appliance is 500mm (20").
The back of the appliance may be installed directly in front of a non-com-
bustible wall, providing the area behind the appliance is flat and does not inter-
fere with the various vent holes in the back panel of the appliance.
Gas Type
Cat
G20
I 2H
Natural
I 3P I 3+
Propane
SIT 9110/ Copreci 21100 2F/ 296
(e.g. 3.8m x 3.8m x 2.425m or 12'5" x 12'5" x 8').
3
Inlet/Operating
Max Energy Input (kW)
Pressure (±2.0 mbar)
G25
G30 G31
20
-
-
-
-
-
-
37
NG Models
Stereo size 1.30
Teddington TESA 3173/011
8mm restrictor elbow
Battery Spark
3.5 - 4.5mm
Figure 2
3
Min Energy Input (kW)
Gross
Net
3.1
2.8
3.1
2.8
LPG Models
Stereo size 83
Teddington TESA 3173/011
8mm restrictor elbow
Battery Spark
3.5 - 4.5mm
) divide the room volume in cubic
3
© 2016 Focal Point Fires plc.
GB IE
Gross
Net
1.5
1.35
1.5
1.35
TBC