4.1 VENTILATION

If the room in which the appliance is installed is naturally ventilated, a minimum of 100 cm
vided for this appliance. This may be achieved either with one vent 100 cm
50 cm
to be installed at high level and 50 cm
2
required. To reduce the possibility of draughts, road noise or insects entering the room via the air vent, we recommend an air vent of
the type that feature internal baffles. Ventilation fitted under, or within immediate vicinity of the appliance must not be used as it may
adversely affect performance of the ODS system. The appliance shall not be installed within one metre of any existing air vent, and any
new air vent shall not be installed within one metre of the appliance.
If the room in which the appliance is to be installed is served by heat recovery ventilation (HRV) or energy recovery ventilation (ERV)
then no purpose provided ventilation is required but a room air change rate of at least one air change per hour is required for this appli-
ance. The appliance MUST be interlocked with the ventilation system such that it is only possible to operate the appliance if the venti-
lation system is in operation. In all cases, the requirements of any other gas, oil or solid fuel appliances operating in the same room or
space must be taken into consideration when assessing ventilation. All ventilation must communicate directly with outside air and must
not pass through rooms or voids unless ducted. Any ventilation fitted must comply (where applicable) with BS 5871 part 4 and BS 5440
part 2. For Republic of Ireland refer to the current edition of IS813 and any relevant rules in force.

5.0 UNPACKING THE APPLIANCE

Remove the outer packaging, remove any instructions. Read ALL these instructions before continuing to unpack or install this appliance.
Lift off the remaining packaging components and remove the contents of the box. Check that the components supplied correlate with
the component checklist. Please dispose of all the packaging materials at your local recycling centre

5.1 COMPONENT CHECKLIST

6.0 GAS SUPPLY ROUTES

All installation pipework must be in accordance with the current edition of National reg-
ulations/codes and the rules in force.
In order to avoid unnecessary pressure drops, use of small diameter pipe should be kept
to a minimum, for example, we recommend no more than 1.5 metres of 8mm pipe. If a
concealed gas connection is to be made, the supply pipe should always be sleeved
through walls and floors using the shortest possible route. For concealed supply pipe
routing, pipes must (where possible) be vertical and providing there is sufficient wall
thickness available, they should be placed in pipe chases. Horizontal pipe runs should be
avoided. Prior to chasing a solid wall, an inspection should be made to note the prox-
imity of any cables/sockets outlets which may be buried. Pipes must be secured using
suitable clips and protected against corrosion. Ideally factory finished protected
pipework and fittings should be used. Joints should be kept to a minimum and compres-
sion fittings must not be used. The pipework installation must be tested for tightness
before any protection is applied and/or the pipework and fittings are buried.

7.0 FIXING THE APPLIANCE

Position the stove in the proposed final location in accordance with sections 3.0, 3.1, 4.0, 4.1 and 6.0. If the hearth or floor surface is
uneven, there are two adjustment feet that can be fitted behind the front two cast legs. Unscrew in a anti clockwise orientation to
extend the feet and clockwise to contract the front legs. The horizontal alignment of the stove may be checked with a spirit level.
Ensure that the stove sits on the adjustment feet not the legs as they prevent the fire from sliding on smooth surfaces.
to be installed at low level within the room. An openable window or equivalent is also
2
QUANTITY
1
1
1
1
1
1
1
2
1
2
2
purpose provided ventilation MUST be pro-
²
at a high or low position in the room, or split ventilation i.e.
2
DESCRIPTION
Stove assembly
Set of manufacturers instructions
Control handle
Decorative handle
M6 x 15mm
Control handle position marking sticker
Log set (1 x Front & 2 x Rear)
Levelling feet
Tiled ceramic set (2 x side panels & 1 x back)
No.8 x 5/16" screws
"L" brackets
Figure 7