Download Print this page

Important Notes; Installation Requirements; Appliance Data - Focal Point MALMO Installation & User's Instructions

Led electric stove

Advertisement

1.0 IMPORTANT NOTES - CONTINUED
• DO NOT run the mains cable under carpets, rugs etc.
• DO NOT cover or obstruct the heater in any way. Overheating will result if it is
accidentally covered.
• DO NOT use the appliance outdoors.
• Never immerse the product in water or any other liquids.
• Before cleaning the appliance, ensure it is unplugged from the power and that it is
• DO NOT clean the appliance with abrasive chemicals.
completely cool.
• Never use accessories that are not recommended or supplied by the manufacturer. It
• DO NOT insert or allow foreign objects to enter the inlet or outlet vents as this
could cause danger to the user or damage to the appliance.
• DO NOT install the fire using an extension cord.
may result in electric shock, fire or damage to the appliance.
• Unplug from the mains supply if the appliance is not to be used for long periods.
• This product is only suitable for well insulated spaces or occasional use.

2.0 INSTALLATION REQUIREMENTS

The appliance is supplied with a pre-wired three pin BS1363 plug (10 Amp fuse rated) and 1.5 metres of electrical flex. It is therefore
necessary for a suitable electrical socket to be located within this distance of the appliance and be easily accessible. The stove may be
installed on a combustible or non-combustible floor, however the heater outlet is underneath the stove and certain types of floor cov-
ering may be affected by the heat produced by the stove. The ability of the floor covering to withstand the heat produced by the stove
should be ascertained before proceeding with the installation of the stove. If in doubt then the stove should be mounted on a non-
com-bustible hearth or plinth which extends for at least 150mm in front of the stove. This appliance should be positioned on a firm
level sur-face. If the stove is to be sited in a fire surround then the suitability of the surround for use with electrical heaters should be
estab-lished with the fire surround manufacturer. If fitted into an open draught fireplace, it is advisable to block off the chimney to
reduce the risk of draught through the stove which may cause the safety cut out system in the fan heater to operate. If you are placing

3.0 APPLIANCE DATA

the heater in an alcove, make sure that there is at least 150mm of space on all sides to ensure good air circulation.
Supply Voltage and rating power : 220-240V ~ 50Hz, 1800W
Heating Elements :
Location :
Model
ND-18D3CL
Item
Symbol
Heat output
Nominal
Pnom
heat output
Minimum heat
Pmin
output
(indicative)
Pmax, c
Maximum
continuous heat
output
Auxiliary electricity consumption
At nominal
elmax
heat output
At minimum
elmin
heat output
In standby mode
elSB
2 x 900W
Indoor use only
Value
1.8
0.9
1.8
0.012 (fan motor)
0.012 (fan motor)
0.0
Fuse Rating :
Lighting :
Supply plug/cord : BS1363/1.5 metres length
Unit
Item
Types of heat input, for electric storage local
space heaters only
KW
Manual heat charge control with
integrated thermostat
KW
Manual heat charge control with
room and/or outdoor temperature
feedback
KW
Electronic heat charge control with
room and/or outdoor temperature
feedback
Fan assisted heat output
Type of heat output/room temperature control
KW
KW
Single stage heat output and no
room temperature control
KW
Two or more manual stages no tem-
perature control
With mechanical thermostat room
temperature control
With electronic room temperature
control
Electronic room temperature con-
trol plus day timer
Electronic room temperature con-
trol plus week timer
3
GB IE
10 Amp
LED
Unit
N/A
N/A
N/A
N/A
No
No
Yes
No
No
No
©