Figure 1; Do Not Block; Important Notes - Focal Point EKO 6010 Installation & User's Instructions

High efficiency gas stove
Table of Contents

Advertisement

U S E R

1.0 IMPORTANT NOTES

• The installation and servicing of this fire MUST only be carried out by a correctly quali-
fied GAS SAFE registered person.
Before you let your gas engineer into your home to work on your gas appliances make sure
you check the front and back of their Gas Safe ID card. If they don't show this to you when
they turn up at your door then don't be afraid to ask to see it. The card is there for your
protection. Make sure that you check the front and back of the card. Check the front of
the card for: the photo, the start date and expiry date, the licence number, the security
hologram and that the engineer is from the business you employed.
Check the back of the card to make sure your engineer is qualified to do the gas work you
want to be done, which in this case is "Fire" and "Pipework". Check their qualifications are
up to date.
You can also check that your engineer is Gas Safe registered by calling Gas Safe Register
on 0800 408 5500, using the check an engineer online at www.gassaferegister.co.uk or by
texting Gas followed by the engineers licence number to 85080. Please note: Your provider
may charge a standard network charge to use the text service.
If you suspect a gas fitter is illegal you can call Gas Safe Register on 0800 408 5500 and
report them or use the online report an illegal gas fitted service.
• All work on this appliance must be in accordance with local Codes and/or Regulations,
Building Regulations and the manufacturer's instructions. Failure to comply with the above could lead to prosecution and invalidate the
appliances warranty. In the event of a gas leakage from the appliance, the gas supply must be turned off at the nearest isolating valve.
This appliance is only suitable for the gas type for which it is supplied.
• Keep a note of the installer's name and address, Gas Safe Registration number and the original purchase receipt and the date of instal-
lation. Failure to produce this information may invalidate the warranty. The appliance should be serviced regularly to ensure continued
safe operation. See servicing section for further reference.
• The guard (glass front) is to prevent the risk of fire or injury from burns and no part of it should be permanently removed. It Does
Not Give Full Protection For Young Children Or The Infirm. Parts of this appliance become naturally hot during use. It is rec-
ommended that a suitable fireguard is used, especially where young children , pets, the elderly or infirm are concerned. The manufac-
turer of this appliance considers all surfaces as working surfaces with the exception of the control knob and immediate area behind.
• Combustible items, such as flooring and furniture or soft wall coverings (such as blown vinyl or embossed paper), low temperature
surrounds etc may discolour if fitted too close to the fire. See relevant section for further details on clearances to combustibles. No
combustible materials or flooring should protrude onto the hearth (if fitted).
• This appliance incorporates a combustion monitoring system (ODS)
• DO NOT burn any foreign material on this fire. Under no circumstances shall the appliance be used if the glass front door or panel
has been removed, damaged or is open. On no account should the appliance inlet or outlet openings be blocked or obstructed in any
way (see figure 1). DO NOT place objects on top of the appliance.
• WARNING: Due to the nature of this product the area around the top of the appliance (i.e. the grille) gets very hot. Care should
be taken when operating the appliance.
The integral catalysts should be checked by the installer upon servicing to ensure there are no defects or obstructions that may pre-
vent the satisfactory flow of combustion products. The expected life of the catalyst is in excess of 11,000 hours (10 years of normal
use). After this time the catalyst should be replaced.
• Should any home improvements be carried out to the property after the fire is installed, such as installation of extractor fans for
example, the fire should be re-checked by a competent person for safe operation.
• This appliance may be installed in any room in the home except bathrooms. In accordance with BS5871 part 4, installation in bed-
rooms is permitted. If the appliance is to be installed in a bedroom then an electric carbon monoxide detector complying with the
current edition of BSEN 50291 must be installed in the same room as the appliance. For maximum safety it is recommended that such
device is continuously (mains) powered and arranged in such a way that the gas supply to the appliance is isolated in the event of an
alarm. The selection and installation of such device shall be in accordance with the current edition of BSEN 50292, and the user must
be briefed regarding the use and maintenance of such device.
I N S T R U C T I O N S
Section
Content
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
11.0
12.0
13.0
14.0
15.0
1
Page No
1
2
3
3
4
4
4
4
5
5
5
6
6
7
7
Outlet openings :

DO NOT BLOCK

Inlet openings :
DO NOT BLOCK