Fuel Bed Layout; Operating The Appliance; Combustion Monitoring System; Servicing - Focal Point EKO 6010 Installation & User's Instructions

High efficiency gas stove
Table of Contents

Advertisement

5.0 FUEL BED LAYOUT

Ensure that the fire is off and cool before attempting to remove or
assemble casting.
The stove is supplied with the casting fitted. To access the fuel bed it is nec-
essary to partially dis-assemble the stove. (see figure 8). A no.2 pozi drive
screwdriver will be required for this. The procedure is as follows;
1) Remove the top grille by the two screws in the top of the appliance and
push the rear of the grille down so the opposite end of the grille lifts up.
DO NOT LEVER OFF.
2) Remove the top casting by unscrewing the four screws holding it in place.
3) Unscrew the cross head screw holding the front casting down at the top.
4) Unscrewing the control handle in a anti clockwise orientation. The front
casting is now free to be removed.
5) Remove the glass door by unscrewing the four retaining screws in each
corner.
6) The fuel bed ceramic components may now be removed for cleaning (see
section 9.0 for further details).
7) To replace the ceramic logs, first place the log marked 'A' on the top left
rear ledge behind the burner as shown in figure 9.
8) Place the log marked 'B' on the right rear of the burner as shown in figure 10.
9) Place the log marked 'C' on the front ledge of the burner, behind the return and in front of the gas burner as shown in figure 11.
10) Clean glass panel if required (see section 9.0)
11) Re-fit the glass door after cleaning or inspection, ensuring a good seal.
12) To re-assemble the castings read instructions in reverse order.
Figure 9

6.0 OPERATING THE APPLIANCE

The control handle is located in the centre of the appliance. The con-
trol handle is marked as shown in figure 12.
The pilot is visible behind the centre of the burner.
Move the control handle fully right to the SPARK position, and hold
there for approximately ten seconds. Now release the control han-
dle and the pilot should stay alight. When the pilot light has estab-
lished, move the control handle left to the LOW flame setting. If the
pilot is extinguished during use, wait three minutes before repeating
the ignition procedure. To achieve the HIGH setting, move the control handle left to the HIGH flame setting. The fire can also be set to
operate anywhere between HIGH and LOW by moving the control handle to an intermediate position.
To turn the fire OFF, move the control handle left fully to the position marked 'O'.

7.0 COMBUSTION MONITORING SYSTEM

This fire is fitted with a combustion monitoring safety device (ODS). If the appliance shuts down during use for no apparent reason then
several reasons may be suspected. If a door or window has been opened creating a draught, then pilot disturbance could be the prob-
lem and removal of the draught should resolve this. The appliance can then be re-lit in accordance with the previous section. If pilot dis-
turbance is not the cause, then the ODS safety system may be in operation. Switch the appliance OFF, call in your installer to check the
appliance and ventilation. Remedial work must be carried out as required. DO NOT allow the appliance to be used until the appliance
and installation is passed as safe. If the pilot continues to be extinguished, you must call your installer to check the operation of the complete
appliance.

8.0 SERVICING

The appliance should be checked on an annual basis to ensure it is working safely and that there is no excessive build up of soot. The
frequency of service will depend on usage, but MUST be carried out at least once annually. Servicing must be carried out by a compe-
tent person, such as a GAS SAFE registered installer .
Figure 10
Figure 12
4
Figure 8
Figure 11
GB IE
© 2016 Focal Point Fires plc.