Product Fiche
Supplier's name or trademark; EKO Fires
Model identifier;
Energy Efficiency Class of the model; A
Direct heat output; 2.8 kW
Indirect heat output; N.A.
Energy Efficiency Index; 91
Useful Energy Efficiency at nominal heat output; 100%
Useful Energy Efficiency at minimum load; 100%
Specific precautions that shall be taken when the local space heater is assembled, installed or
maintained;
This appliance must be installed, commissioned and maintained by a competent person. Prior to
installation the competent person must ensure that the local distribution conditions (identification
of the type of gas and pressure) and adjustment of the appliance are compatible.
This appliance must be installed in accordance with the rules in force, and used only in a sufficiently
ventilated space of adequate volume. Consult the instructions before installation and use of this
appliance.
The competent person must refer to and comply with the specific instructions listed in the
Installation Manual before starting to install and commission the appliance.
L35 Flueless Gas Stove
Gas Category/Pressure = I
(20)
2H