Focal Point LASCAR Installation And User Instructions Manual

Flueless gas stove

Advertisement

LASCAR
EXCELSIOR
FLUELESS G G AS S S TOVE
INSTALLATION A A ND U U SER I I NSTRUCTIONS
All i i nstructions m m ust b b e h h anded t t o u u ser f f or s s afekeeping
Revision C - 10/05
Country(s) of destination - GB/IE
Focal Point Fires plc, Christchurch, Dorset BH23 2BT
Tel: 01202 499330
Fax: 01202 499326
www.focalpointfires.co.uk
e-mail: sales@focalpointfires.co.uk

Advertisement

Table of Contents
loading

Summary of Contents for Focal Point LASCAR

  • Page 1 All i i nstructions m m ust b b e h h anded t t o u u ser f f or s s afekeeping Revision C - 10/05 Country(s) of destination - GB/IE Focal Point Fires plc, Christchurch, Dorset BH23 2BT Tel: 01202 499330 Fax: 01202 499326 www.focalpointfires.co.uk...
  • Page 2 INST T ALLAT T ION I I NST T RUCT T IONS P P r r e e l l i i m m i i n n a a r r y y N N o o t t e e s s B B e e f f o o r r e e I I n n s s t t a a l l l l a a t t i i o o n n This appliance is a High Efficiency, Flueless, Live Fuel Effect stove.
  • Page 3: Table Of Contents

    Sec c tion Contents s Pag g e N N o. Sec c tion Contents s Pag g e N N o. Important N N otes Operating the Appliance Appliance D D ata Spark Failure Installation R R equirements Setting Pressure 3.1 Room Sizing 10.0 Briefing t t he C C ustomer...
  • Page 4: Appliance D D Ata

    APPLIANCE D D ATA Gas Group G20 Natural Gas CAT I2H Inlet Pressure 20 mbar Max Energy Input Gross 2.6 kW 2.35 kW Max Gas Rate 0.25 m3/h Min Energy Input Gross 1.5 kW 1.35 kW Pilot Energy Input Gross 166 W 150 W Burner Pressure High...
  • Page 5: Site R R Equirements

    SITE R R EQUIREMENTS ( ( continued) The stove is designed to be versatile, and as such will operate correctly when exposed to normal gentle draughts experienced within the home. It is not recommended, however that the appliance be installed in areas where it is likely to be exposed to persistent strong draughts, that may be generated by outside doors or windows, air vents or other.
  • Page 6: Ventilation

    VENTILATION A minimum of 100 cm purpose provided ventilation is required for this appliance. An openable window or equivalent is also required. The requirements of other flued appliance operating in the same room or space must be taken into consideration when assessing ventilation. Any ventilation fitted must comply with BS 5871 part 2 and BS 5440 part 2.
  • Page 7: Fuel B B Ed L L Ayout

    FUEL B B ED L L AYOUT Place the brick panel against the rear of the firebox, now insert the side panels and push back firmly to secure in place. Place the ceramic combustion matrix onto the burner. Ensure that the hole for pilot flame viewing is clear and easi- ly visible, and the matrix sits level on the burner tray.
  • Page 8: Spark Failure

    SPARK F F AILURE The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark. There should be no need to adjust this. If under any circumstances the piezo electric spark fails, the pilot cannot be lit man- ually.
  • Page 9: Cleaning The Coals

    11.0 SERVICING ( ( continued) 11. Turn on the gas supply and leak test. Check pilot and burner for good ignition. 12. Refit the ceramics as per installation section. 13. Refit the glass door assembly, ensuring a good seal. 14. Refit the casing by tilting the body forward, locating the lugs in their holes and tilting back. 15.
  • Page 10: Catalytic Convertor

    11.4 CATALYST It is recommended that the catalyst is inspected for signs of damage and dirt during routine servicing proce- dures. The expected life of the catalyst is in excess of 11,000 hours (10 years of normal use). After this time the catalyst should be replaced.
  • Page 11: Troubleshooting G G Uide

    12.0 TROUBLESHOOTING G G UIDE Fire s s parks s b b ut p p ilot d d oes s n n ot l l ig g ht No gas to fire, check isolators are open. Pipe work blockage, clean out. Air not fully purged, re purge supply or wait longer.
  • Page 12 USER I I NSTRUCTIONS Sec c tion Content Pag g e N N o Important Notes Clearances to Combustibles Ventilation & Room Size Operating Instructions Combustion Monitoring System Cleaning Ceramics Servicing List of Replacement Parts IMPORTANT N N OTES The installation and Servicing of this fire MUST only be carried out by a competent person (such as a CORGI registered fitter) in accordance with the Gas Safety (Installation and Use) Regulations 1998, the relevant British Standards, Codes of Practice, the Building Regulations and the manufacturer's instructions.
  • Page 13 CLEARANCES T T O C C OMBUSTIBLES Clearance to the sides of the stove are 100mm (4in) but curtains, drapes and other fabrics are not permitted within a distance of 500mm (20in) of the stove sides and back. No such materials are permitted directly above the stove regardless of distance.
  • Page 14 OPERATING I I NSTRUCTIONS ( ( continued) To turn to the PILOT position from the HIGH or LOW positions, press the control knob in, and return to the pilot position and release. To turn the fire OFF, keep the knob pressed in, return to the off position and release. COMBUSTION M M ONITORING S S YSTEM This fire is fitted with a combustion monitoring safety device (ODS).