VERSIONS
STANDARD
The fan is operated using a separate ON/OFF switch or via a light switch (fig. 11A).
WITH TIMER (over-run )
The fan is provided with a timer circuit which is adjustable from aprox. 1 minute to 25 minutes via trimmer (fig. 12B).
Operation: connected according to the diagram in figure 12A, after the light is switched on, the fan activates with a delay of max 1.5 seconds. After
the light is switched off, the fan continues to function for a pre-set period of time.
STANDARD CONFORMITY
2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic Compatibility (EMC),
in conformity with the following standards:
Electrical Safety
EN60335-1(2008); EN 60335-2-80(2005); EN 60335-2-80/A2(2009)
Electromagnetic Compatibility
EN 55014-1(2006)+A1+A2; EN 55014-2(1997)+A1(2001)+A2(2008)+IS1(2007)
EN 61000-3-2(2006)+A1(2009)+A2(2009); EN 61000-3-3(2008).