Sensing values:
(Default NTC 15 K)
0°C
20°C
50°C
Control
Ambient temperature
Frost protection temperature
Temperature range
Sensor failure monitoring
Cable specification max.
Ball pressure test temperature
Pollution degree
Controller type
Software class
Storage temperature
Installation Guide
42 kOhm
18 kOhm
6 kOhm
PWM (Pulse Wide Modulation)
0° to +30°C
5°C to +9°C (default 5°C)
Room temperature: 5-35°C.
Floor temperature: 5-45°C.
Max. floor: 20-35°C (if unrecov-
erable seal is broken then up to
45°C). Min. floor: 10-35°C, only
with combination of room and
floor sensor.
The thermostat has a built-in
monitoring circuit, which will
switch off the heating if the
sensor is disconnected or short-
circuited
2
1x4 mm
or 2x2,5 mm
75°C
2 (domestic use)
1C
A
-20°C to +65°C
2
5