HADEF 43/86P Liftboy-EX Installation, Operating And Maintenance Instruction page 8

Pneumatic wire rope winch
Table of Contents

Advertisement

Example of ATEX classification:
CE-marking
explosion-proof operating material
II
device group / application
2
device category
G
EX atmosphere
Ex h
type of protection
IIB
explosion group II (gases)
Temperature class - gases
T4
(for dust only the temperature in °C
is stated)
Gb
EPL (equipment protection level)
2.6.1
EX-Category
DANGER!
The classification for the device can be found on the EX-type plate on the unit.
The device must only be used in the classification stated or in a lower classification.
2.6.2
Surface temperature of the devices
DANGER!
The temperature class mentioned on the EX-type plate on the unit must be observed, - make sure
that the max. surface temperature is even fallen short of.
DANGER!
The maximum surface temperature of the equipment must always be lower than the ignition
temperature of the gas/vapour/dust/air mixture. Equipment which has been classified in higher
temperature classes is, of course, also approved for use in applications with lower temperature
classes. As gas/air mixtures for T5 do not occur with normal use, and only very rarely occur for T6,
for specific gas/air mixtures such as carbon disulphide (IIC), our hoists are not rated for these
temperature classes and must not be used for these classes.
8
II
2
G Ex h
I
II
1
2
3
G
D
IIA
IIB
IIC
T1
T2
T3
T4
T5
T6
Ga
Gb
Gc
EX - Zone
Device category
Expl.-group of gases
Expl.-group of dust
Temperature class - gases
Temperature class - dust
IIB
European Union
danger of mine damp
other areas prone to explosion
for use in zone 0
for use in zone 1
for use in zone 2
...caused by gas, steam, fog
...caused by dust
for mechanical devices, including e. g.
<c= construction safety
<k= encapsulation of liquids
limit gap widths (MESG) > 0,9 mm
limit gap widths (MESG) f 0,9 to g 0,5 mm
limit gap widths (MESG) < 0,5 mm
limit temperature 450 °C
limit temperature 300 °C
limit temperature 200 °C
limit temperature 135 °C
limit temperature 100 °C
limit temperature 85 °C
e.g. Group II (for gases, vapours, mist):
level of protection: very high (complies with zone 0)
level of protection: high
(complies with zone 1)
level of protection: enhanced (complies with zone 2)
1+21
1+21
2+22
2+22
2
2
IIB
IIB
IIIA
IIIA
T4
T3
T135°C
T200°C
T4
Gb
5.52.289.01.01.04