Installing the Device
2.8 Installing the EMI Gaskets
3.
1
Figure 2.10
EMI Gasket Installation
4.
5.
26
it from the patch panel groove and allow it to sit for 8 hours before
attempting to install it again. The material will return to its original length.
•
Do not cut the gasket to length before assembly.
Starting at the overlapping section of a patch panel groove, gently press a length
of gasket material into the groove. Work around the groove until the gasket is
seated all around the opening and in the overlapping section. Make sure the
gasket material is loose and is not stretched during installation.
Trim the gasket material to length.
Repeat step 3 (Page 26) and step 4 (Page 26) for each patch panel
opening.
RUGGEDCOM MX5000RE
Equipment Manual, 11/2023, C79000-G8976-1060-17
2