Gigaset M101 Data Operating Instruction

The cordless v.24/rs232 interface for pcs, modems and other equipment
Table of Contents

Advertisement

Quick Links

14.4.99
s
The cordless V.24/RS232 interface
for PCs, modems and other
equipment
Operating instruction
Please read the safety precautions outlined in these
operating instructions before putting the unit into service.
ACHTUNG! Schnittkante ggf. auf Titelseite U1 nach außen versetzen wg. Falz-Ausklappseite
coverm1.fm5
Gigaset M101 Data, eng/deut: A30853-X400-B104-3-74D1

Advertisement

Table of Contents
loading

Summary of Contents for Gigaset M101 Data

  • Page 1 PCs, modems and other equipment Operating instruction Please read the safety precautions outlined in these operating instructions before putting the unit into service. ACHTUNG! Schnittkante ggf. auf Titelseite U1 nach außen versetzen wg. Falz-Ausklappseite Gigaset M101 Data, eng/deut: A30853-X400-B104-3-74D1...
  • Page 2 16.4.99 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 The most important menus Starting the program Registering a Gigaset M101 Data Setting the operating mode...
  • Page 3 klapps1.fm5 16.4.99 Overview 1 2 3 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Legend Front Operating LED, illuminated when power supply is active, see "LEDs and buttons" on page 2. Data LED, illuminated during data transfer operations 3. Reset key Back 4. Port for the V.24/RS232 cable 1 = male 2 = female...
  • Page 4: Table Of Contents

    Notes on PC and modem operation ... 6 Notes on Gigaset Repeater ... 6 Introduction ... 7 What is a Gigaset M101 Data? ... 7 Safety precautions ... 7 Putting into service ... 8 Checking the contents of the package ... 8 Important ...
  • Page 5: Updates And News On The Internet

    Configuration management ... 35 Problems with application programs: ... 35 Hardware problems (PC, modem, ISDN TA.): ... 36 Miscellaneous ... 37 Updates and news on the Internet Visit our site at: www.siemens.com/pc-communication-support (always under construction) Gigaset M101 Data, eng/deut: A30853-X400-B104-3-74D1 Contents...
  • Page 6: Approval And Conformity

    Notes on PC and modem operation Notes on Gigaset Repeater Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Your Siemens Gigaset M101 Data has been certified by the Ger- man Federal Office of Telecommunication Approval (BZT). This equipment has been approved in accordance with the EU direc- tive 91/263/EC Telecommunication Terminals.
  • Page 7: Introduction

    M101 Data connected to the PC automatically switches to a "Teilnehmer" type station. The Teilnehmer station must be reg- istered at the Basis station. Every Gigaset M101 Data can be operated either as a lokale Sta- tion or as a Partnerstation. Research has shown that in certain cases, medical equipment can be affected by activated DECT devices.
  • Page 8: Putting Into Service

    V.24/RS232 interface CD-ROM with the installation program Operating instructions Before you put the Gigaset M101 Data into service, the peripheral device that you want to operate as a cordless unit (modem, PABX) must be configured at the COM port on the PC side since it is to be used for transferring data.
  • Page 9: Installing The Program Package

    If no errors occur, all files are installed in the selected language version and your PC contains a "Gigaset M101 Data" program group. This contains the "Set Gigaset" configuration program, a help function and a text file with current information.
  • Page 10: Connecting Stations

    Putting into service Connecting stations Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 To avoid damaging your Gigaset M101 Data and the PC, the V.24/RS232 cable should only be connected when the pow- er supply is switched off. Connect a Gigaset M101 Data to the V.24/RS232 interface of the PC (COM port).
  • Page 11: Initial Configuration

    Disconnect both stations and the PC from the power sup- ply. 2. Connect one Gigaset M101 Data to the PC. 3. Connect the PC and both Gigaset M101 Data units to the power supply. 4. Start the program "Set Gigaset" at the PC.
  • Page 12: Configuration Program Options

    Set Gigaset. The configuration program offers a dialog box entitled Proper- ties of Gigaset M101 Data which contains the four tabs Connec- tion, Operating mode, Local station and Partner station. A number of special fields are also provided for special inputs.
  • Page 13: Connection" Tab

    This is indicated by the Status display in the dialog box. Gigaset M101 Data can only be configured under these condi- tions. At the end of the program, your Gigaset M101 Data will automatically switch the station back to operating mode.
  • Page 14: Operating Mode" Tab

    The appropriate switches are performed automatically if you select an operating mode for an Gigaset M101 Data unit. Open the Operating mode tab and select one of the five modes: The three connection types are used for different purposes: Direct connection The transmission parameters for the PC’s...
  • Page 15: Special Settings For "Direct Connection" Mode

    gigam101.fm5 21.4.99 Special settings for "Direct connection" mode "Local station" tab Changing a name Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Configuration program options AVM / Eumex Automatic emulation of the AVM / Eumex Partnerstation transmission parameters based on the val- (device) ues received from the PC at the Partner- station.
  • Page 16 PC or the modem alternate- ly. It may be necessary to change the station type in the case of a Gigaset M101 Data. Ensure that the correct station is connected locally. Select Change station type. The change is performed in the background.
  • Page 17: Registering An Extension Station

    21.4.99 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Configuration program options Registering an Teilnehmer station Both stations are powered. A Gigaset M101 Data is connected to the PC. Select the Local station tab. The following dialog box appears: An existing registered device in the "Registered stations" win- dow must first be deleted.
  • Page 18: De-Registering A Extension Station

    This tab is used for configuring the Partnerstation that is not connected to the PC. The registration must be performed first so that the two Gigaset M101 Data devices can communicate: the "Partner station" tab only becomes operational after registra- tion on the "Local station"...
  • Page 19: Leds And Buttons

    Both button functions Setting a Basis to logon mode Resetting the device to the factory default LED 1: Gigaset M101 Data status LED 2: data transfer Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 There are two LEDs and a black button on the front of the Gigas- et M101 Data unit.
  • Page 20: What Happens If

    If the malfunction still occurs after checking all the above points, reset both Gigaset M101 Data units to the factory defaults, see page 19. If the malfunction persists, call the hotline at 0180 5 333 220.
  • Page 21: Temperature And Ambient Conditions

    The Gigaset M101 Data is designed for operation in protected rooms with a temperature range from +5°C to +45°C. Do not set up the Gigaset M101 Data in damp environments, such as a bathroom or laundry room. Do not expose it to direct sunlight or other heat sources, such as radiators.
  • Page 22: The V.24 Interface

    appendix.fm5 16.4.99 The V.24 interface Name Based on CCITT 109 = Data Carrier Detect 106 = Clear To Send 107 = Data Send Ready 108 = Data Terminal Ready 102 = Signal Ground 105 = Request To Send 104 = Receive Data 103 = Transmit Data 125 = Ring Indicator Transmitter...
  • Page 23: Why Set A Mode? Technical Background

    2. AT or AVM/Eumex commands, local: this is the operating mode for the lokale Station: the local Gigaset M101 Data de- termines the conditions on the serial interface in the same way as a modem and transmits data as well as information to the Partnerstation on the transmission parameters to be used for entering this data in the terminal.
  • Page 24: Tips & Tricks, Settings

    Only one connection can be active. Only one "Teilnehmer" station type can be registered at a base that is ready for registration. The station type for Gigaset M101 Data units is set to "Basis" by default. Perform registration as described in the section "Initial configu- ration"...
  • Page 25: Pc - Pc Direct Cable Connection: Via Rs232/V.24 Interface

    If this is not possible, the precise configuration should be observed. Gigaset M101 Data can be set to a fixed baud rate (direct connection 115,200 bps with HW handshake). 1 similarly for WIN98...
  • Page 26: Setting The Direct Connection To The Correct Baud Rate

    appendix.fm5 16.4.99 Tips & tricks, settings Setting the direct connection to the correct baud rate Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Open the terminal program The first step is to open a terminal program on both PCs (e.g. Win95 HyperTerminal via Hypertrm.exe) and to ensure that the correct COM port is being accessed, Set up a direct connection via COMx (COM 1 is selected in the example).
  • Page 27 appendix.fm5 16.4.99 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Tips & tricks, settings The baud rate (max. 115,200) and HW handshake (default setting) are set in this mask. If you are able to transmit data from one PC to the other, proceed now to the second step. 2.
  • Page 28 appendix.fm5 16.4.99 Tips & tricks, settings Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 You will find maximum speed setting in the Modem tab; this should be set to 115,200 bps. Activate Hardware under Use flow control in the Settings - Advanced tab. Click OK to exit each window. 3.
  • Page 29 appendix.fm5 16.4.99 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Tips & tricks, settings Select Modify under Settings and activate Guest. Enter the port, e.g. “Null-Modem Cable at COM 1” . To enable access by the other PC, the host (controlling) and guest (accessing), as well as the file and print sharing option must be activated.
  • Page 30 appendix.fm5 16.4.99 Tips & tricks, settings Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Click File and Print Sharing in the sub-window. Set the parameters here. If a modification was made, new drivers are loaded and Windows must be restarted. If file and print sharing was already activated, the computer does not need to be restarted.
  • Page 31 appendix.fm5 16.4.99 Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Tips & tricks, settings If the computer was not restarted, the following window ap- pears: If file/printer sharing has not yet been activated, you can activate this feature, see "Sharing files" on page 32. In the final window, select Finish and click OK to answer the questions.
  • Page 32: Sharing Files

    appendix.fm5 16.4.99 Tips & tricks, settings Sharing files Gigaset V.24 Adapter dt/eng:A30853-X400-B104-3-74D1 Since the Windows information given in the previous mask is somewhat confusing, and since no references are made to the File Manager/Explorer, here is the correct procedure. Once file sharing has been activated and the PC restarted, you can re- lease files for processing by the other PC via the File Manager/ Explorer.
  • Page 33: Pc - Pc Direct Cable Connection Problems: Examples

    Data unit is connected to the correct device. To do this, we rec- ommend that you place a sticker, e.g. marked modem or PC, un- der the Gigaset M101 Data unit so that the correct device is con- nected later.
  • Page 34: Support

    However, interference can still occur due to a bad radio link. If you have problems with this setting, start the configuration pro- gram and check the transmission quality under Connection. This can be changed by moving the Gigaset M101 Data unit slightly.
  • Page 35: Configuration Management

    16.4.99 Configuration management Fault Configuration program displays the message "A Gigaset M101 Data could not be found". Configuration on an Apple Mac- intosh with "Virtual PC" is not working. Configuration program displays the message "Could not register at the base".
  • Page 36: Hardware Problems (Pc, Modem, Isdn Ta.)

    X.75 connection is set up with the modem profile "ISDN ELSA TLV34 X.75 64,000". Incorrect protocol set. Set Gigaset M101 Data to 300 bps direct connection. Data flow setting: without. The initialisation string is incor- The character "/" must be re- rect.
  • Page 37: Miscellaneous

    ELSA Microlink 56k and WinFax 8.0 software. Miscellaneous Fault Monitor fault when Gigaset M101 Data is active (e.g. slight flickering or moiré effect). A slight humming can be heard in the loudspeakers connected to the sound card when Gigaset M101 Data is active.

This manual is also suitable for:

Rs232Gigaset m101 data

Table of Contents