12. OPERATION
12.1.2.8
CHECK OIL LEVEL IN HYDRAULIC TANK, ADD OIL
/
A ,W-G
:,
When removing the oil tiller cap oil may spurt out so stop the engine
and wart for the 011 temperature to go down then turn the cap slowly
to release the internal pressure before removing the cap.
1. Check the hydraulic oil level in the tank at the sight gauge. The proper
level is when cold;
At bottom of sight gauge.
when hot;
At center of sight gauge.
Add oil as required.
2. Open the right side door at the hydraulic reservoir.
3. Remove the filler cap and add oil to the proper level. Install filler cap.
REMARK
For details of the oil to use, see 20. USE OF FUEL, COOLANT AND
LUBRICANTS
ACCORDING
TO AMBIENT TEMPERATURE.
I
I
4. Lift up on lock lever and close door.